36
SDA³ / SDA³ E - Rev.04 - Mar / 22
6. Set-up instructions
B
B
Procedures to change the spacing
A
A
E
E
C
C
D
D
- Check if the equipment is well supported to avoid accidents.
ATTENTION!
To change the spacings of the seeder, proceed as follows:
- Change the spacing on a clean, flat and firm location. Make sure that the seeder is
properly supported;
- Release the row units by loosening the nuts (A and B). Remove only the row units
which will not be used, the other ones should be kept or displaced in the equipment;
- Remove the seed (C) and fertilizer (D) tubes, along with the row units, releasing the
clamps that hold the nozzles;
- Close the seed outlets with the switch (E) on the removed row units.