TATSUNO
EUROPE
a.s.,
www.tatsuno
‐
europe.com
88
Table
13
‐
Label
information
on
the
dispenser
and
module
TATSUNO
EUROPE
a.s.
Name
and
address
of
dispenser
manufacturer
1383
Dispenser
labelling
means
that
it
is
designed,
manufactured
and
labelled
in
accordance
with
European
Commission
directives.
The
dispenser
is
subject
to
a
type
examination
certification
in
accordance
with
Directive
2014/32/EU
‐
MID
which
was
carried
out
by
a
notified
body
No.
1383
‐ Č
MI
Brno
1026
Dispenser
labelling
means
that
it
is
designed,
manufactured
and
labelled
in
accordance
with
European
Commission
directives.
The
dispenser
is
subject
to
the
type
‐
examination
certification
in
accordance
with
Directive
2014/34/EU
‐
ATEX
which
has
been
carried
out
by
a
notified
body
No.
1026
‐
FTZÚ
Ostrava
Radvanice
LIQUID
FUEL
DISPENSER
Device
identification
Type
of
Marking
of
the
dispenser
type
(see
section
2.4)
MID
certificate
Number
of
the
metrology
EU
certificate
approving
the
meter
type
–
Č
MI
ATEX
certificate
Number
of
the
EU
certificate
of
type
examination
(ATEX
certificate)
–
FTZÚ
Serial
number
Serial
number
of
the
dispenser
(seq.
number
/
year
of
production)
Fluid/medium
temperature
range
Range
of
delivered
liquid,
medium
or
gas
temperature
for
which
the
dispenser
was
designed
and
approved
Ambient
temperature
range
Range
of
ambient
temperature
for
which
the
dispenser
was
designed
and
approved
Pressure
min/max
Minimum
and
maximum
working
pressure
Accuracy
class/mech/elm.
Accuracy
class
/
Mechanical
class
/
Electromagnetic
class
diesel,
gasoline,
LPG,
AdBlue...
Type
of
liquid,
medium
or
gas
for
which
the
dispenser
was
designed
and
approved
Q
max
Maximum
pumping
/
filling
flow
rate
in
L/min
or
kg/min
Q
min
Minimum
pumping
/
filling
flow
rate
in
L/min
or
kg/min
MMQ
Minimum
consumption
in
L
or
kg
II
2G
IIA
T3
Identification
of
the
protection
of
a
non
‐
explosive
electrical
device:
II
2
–
device
for
environment
with
an
explosion
hazard
other
than
subsurface
mines,
probability
of
explosive
atmosphere
occurrence
–
zone
1
G
–
explosive
atmosphere
is
formed
by
gases,
vapours
or
mists
IIA
–
gas
group
–
the
least
dangerous
T3
–
maximum
temperature
of
an
electrical
device
that
could
cause
ignition
of
the
ambient
atmosphere
(200°C)
EN
13617
‐
1;
EN
14678
‐
1
Number
of
the
European
standard
under
which
the
dispenser
was
approved
motor
power
supply
3x400/230V;
2A;
50Hz;
0,75kW
Figure
60
‐
Nameplate
of
two
‐
hose
LPG
dispenser
Figure
61
‐
Nameplate
of
two
‐
hose
AdBlue®
dispenser
Figure
62
‐
Nameplate
of
two
‐
hose
WSE
dispenser
Figure
63
‐
Nameplate
of
two
‐
hose
CNG
dispenser