158
Figure
90
–
Piston
meters
of
fuel
(type
FM
‐
1007)
and
LPG
(type
MP
‐
02524
and
FM
‐
1029),
A=calibration
wheel
Manual
electronic
calibration
of
the
meter
is
performed
on
all
types
of
meters
by
manually
changing
the
counter
parameter:
for
the
PDEX5
counter
by
changing
the
value
of
the
correction
factor
in
parameter
M6
‐
P09
(the
default
value
of
the
parameter
is
10000,
which
corresponds
to
a
correction
factor
of
1.0000)
for
the
PDEX
counter
by
changing
the
value
of
parameter
P44
,
which
indicates
the
number
of
pulse
generator
pulses
for
filling
1L
of
fuel
(the
standard
value
of
the
parameter
is
10000,
which
corresponds
to
the
value
of
100.00
pulses
per
liter)
for
the
PDELTx
counter,
by
changing
the
value
of
parameter
P14,
P15,
P16
or
P17
,
which
indicates
the
number
of
pulse
generator
phases
for
filling
1L
of
fuel
(default
parameter
value
is
400
which
corresponds
to
400
pulse
phases
per
litre
=
100
pulses
per
litre)
The
parameter
value
can
only
be
changed
after
switching
switch
SW1
‐
1
to
the
OFF
position
and
using
the
yellow
service
remote
controller
PDERT
‐
5S
(see
figure
on
the
right).
Switch
SW1
‐
1
is
protected
by
a
cover
and
a
seal.
The
procedure
for
manual
electronic
calibration
of
the
meter
is
as
follows:
1)
Accurate
fuel
delivery
is
performed
into
the
calibrated
vessel
(e.g.,
20L)
2)
According
to
the
dispenser
display
value,
the
corrected
parameter
value
is
read
from
the
calibration
table
(see
Table
38).
E.g.
when
filled
20L
calibrated
vessel,
the
value
19.95L
appears
on
the
display,
which
is
according
to
Table
38,
out
of
tolerance
by
‐
0.25%
and
the
corrected
value
of
parameter
M6
‐
P09
is
10025
(for
PDEX5
counter)
or
corrected
value
of
parameter
or
the
corrected
value
of
parameter
P44
is
9975
(for
PDEX
counter).
22.42
19.95
1.124
9975
44
1
M6
10025
P09
‐
1
PDEX5
PDEX