TATSUNO
EUROPE
a.s.,
www.tatsuno
‐
europe.com
110
4.
DISPENSER
SETTING
AND
BASIC
FUNCTIONS
Dispenser
setting
is
performed
by
the
set
of
setting
parameters
via
which
it
is
possible
to
control
functional
parameters
of
the
dispenser,
totally
change
the
mode
and
behaviour
of
the
dispenser
in
different
situations.
Depending
on
the
type
of
an
electronic
counter
installed
the
parameter
values
can
be
viewed
and
changed
using
the
remote
IR
(infrared)
controller,
the
service
keypad,
or
the
pre
‐
set
keypad
buttons
located
on
the
dispenser.
Table
26
describes
the
basic
parameters
of
all
electronic
counters
used
in
TATSUNO
EUROPE
dispensers.
Table
26
‐
Types
of
TATSUNO
EUROPE
electronic
counters
Counter
type
PDEX
TBELTX
TBELTM
PDEX5
Year/month
of
first
installation
06/2008
06/2010
01/2016
5/2018
Use
all
types
of
dispensers
all
types
of
dispensers
without
temperature
compensation
and
without
the
“Slave”
display
dispensers
with
a
mass
meter
(CNG
and
LPG)
all
types
of
dispensers
OIML
verification
R117
R117
R117,
R139
R117
MID
Evaluation
certificate
no
no
yes
yes
Software
Validation
(WELMEC
7.2)
yes
yes
yes
yes
Method
of
parameter
setting
Remote
controller
PDERT
‐
XS,
service
PDERT
‐
XO,
manager
External
keyboard
or
pre
‐
set
keypad
Remote
controller
PDERT
‐
XS,
service
PDERT
‐
XO,
manager
Remote
controller
PDERT
‐
XS,
service
PDERT
‐
XO,
manager
View
program
version
+
CRC
after
powering
on
or
in
parameter
P05
‐
1
(version)
P05
‐
2
(CRC)
after
powering
on
or
in
parameter
P51
(CRC)
P53
(version)
after
powering
on
or
in
parameter
P05
‐
1
(version)
P05
‐
2
(CRC)
after
powering
on
or
in
parameter
M0
‐
P05
‐
1
(version)
M0
‐
P05
‐
2
(CRC)
Protection
of
metrological
parameters
by
a
password
+
switch
by
a
switch
by
a
password
+
switch
by
a
password
+
switch
Communication
protocol
type
PDE
(RS485)
PDE
(RS485)
PDE
(RS485)
PDE
(RS485)
The
method
of
setting
the
dispenser
differs
depending
on
the
counter
used
in
the
dispenser
head.
The
following
section
describes
the
basic
functions
and
settings
for
all
counters.
4.1.
PDEX5
COUNTER
The
PDEX5
electronic
counter
is
set
using
the
remote
controller.
The
yellow
service
remote
controller
PDERT
‐
5S
is
intended
for
service
engineers
authorized
by
the
dispenser
manufacturer.
This
remote
controller
allows
to
perform
complete
settings
of
all
dispenser
parameters.
The
silver
remote
controller
PDERT
‐
5O
is
intended
for
fuel
station
managers
and
this
remote
controller
allows
them
to
perform:
reading
non
‐
resettable
electronic
litre
totalizers
of
all
delivery
hoses
reading
and
resetting
daily
electronic
litre
and
financial
totalizers
of
all
hoses
setting
of
unit
prices
of
products
(in
manual
operation)
reading
and
setting
of
operating
parameters
of
the
dispenser
The
setting
mode
may
be
called
up
at
the
dispenser
by
a
below
stated
procedure
only
in
the
condition
when
the
dispenser
is
at
rest
‐
i.e.,
in
the
condition
of
“finished
delivery”,
all
nozzles
hung,
all
sales
finished.
There
are
two
access
modes: