TATSUNO
EUROPE
a.s.,
www.tatsuno
‐
europe.com
116
4.1.8.
FUEL
PRODUCT
UNIT
PRICES
(P03)
This
feature
allows
you
to
view
and
set
current
unit
prices
(i.e.,
one
litre
of
fuel)
of
all
fuel
products.
These
fuel
unit
prices
are
set
on
the
display
at
the
first
lift
of
the
delivery
nozzle
and
reset
of
the
display
if
the
dispenser
works
in
the
manual
mode
.
Setting
is
made
by
pressing
the
<E>
key
and
entering
the
price
in
the
<PPPP>
format
and
confirming
by
the
<E>
key.
The
decimal
point
is
not
entered.
E.g.,
unit
price
1.03
€/L
is
entered
as
number
0103,
price
34.15
CZK/L
as
number
3415,
etc.
Parameter
Meaning
Factory
setting
P03
‐
1
fuel
product
unit
price
1
0,00
€/L
P03
‐
2
fuel
product
unit
price
2
0,00
€/L
P03
‐
3
fuel
product
unit
price
3
0,00
€/L
P03
‐
4
fuel
product
unit
price
4
0,00
€/L
P03
‐
5
fuel
product
unit
price
5
0,00
€/L
NOTE
Number
of
fuel
products
shown
in
the
P03
parameter
is
conditioned
by
the
configuration
of
the
dispenser.
The
identification
system
of
delivery
hoses
and
products
is
described
in
Figure
77.
if
you
change
the
unit
price,
such
change
will
be
reflected
after
a
subsequent
lift
of
the
delivery
nozzle.
NOTICE
Values
set
in
the
P03
parameter
are
valid
in
the
dispenser
manual
mode
only.
If
the
dispenser
is
connected
to
the
central
control
system
of
the
fuel
station,
then
the
fuel
unit
price
is
set
directly
by
the
control
system
before
each
delivery.
In
such
case
the
values
of
the
P03
parameter
are
non
‐
functional.
NOTICE
The
dispenser
does
not
enable
deliveries
with
a
zero
value
of
the
unit
price.
In
such
case,
after
lifting
the
delivery
nozzle
the
dispenser
display
shows
the
error
message
E30
and
the
delivery
does
not
start.
4.1.9.
CURRENT
TIME
AND
DATE
(P04)
This
function
allows
to
view
and
set
the
current
time
and
date.
The
setting
is
made
by
pressing
the
<E>
key
by
entering
the
time/date
in
the
correct
format
and
confirming
with
the
<E>
key.
NOTE
The
time/date
information
is
used
by
parameters
P20
to
P34
to
record
the
exact
moment
of
the
fault,
end
of
delivery,
change
of
dispenser
control
mode…,
etc.
The
date/time
data
has
only
an
informative
function,
it
does
not
affect
the
process
of
fuel
delivery.
NOTICE
The
internal
clock
is
reset
at
least
5
days
after
the
power
supply
off.
Time
and
date
values
will
switch
to
factory
setting
and
must
be
set
again!
Parameter
Meaning
Factory
setting
P04
‐
1
Time
setting,
format
HHMMSS
(i.e.,
125600
=
12:56:00)
0:00:00
P04
‐
2
Date
setting,
format
DDMMYY
(i.e.,
230821
=
23.
08.
2021)
1.1.2001
time
125600
P04
‐
1
date
230821
P04
‐
2