Fuel
Dispensers
TATSUNO
EUROPE
‐
Installation
and
User
Manual
,
revision
10,
January
2022
27
2.3.
BASIC
TECHNICAL
PARAMETERS
Table
8
–
Dispensers
and
modules
(gasoline,
diesel,
biodiesel,
mixed
diesel,
E85,
aircraft
fuel)
Pumping
performance
Standard
Increased
(/H)
Very
high
(/UH)
Maximum
flow
rate
Q
max
[L/min]
30
to
50
70
to
80
120
to
170
Minimum
flow
rate
Q
min
[L/min]
3
to
5
*
5
10
Lowest
metering
MMQ
[L]
2
5
10
Maximum
pressure
[MPa]
‐
suction
version
‐
pressure
version
0.18
0.25
0.25
0.35
Minimum
pressure
[MPa]
0.16
Maximum
unit
price
(number
of
digits)
9999(4)
or
99999(5)
**
Maximum
amount
to
pay
(number
of
digits)
999999(6)
or
9999999(7)
**
Maximum
volume
(number
of
digits)
999999(6)
or
1999999(6.5)
**
Scale
interval
[L]
0.01
Display
type
Electronic
Type
of
delivered
fluid
Gasoline,
diesel,
biodiesel,
mixed
diesel,
ethanol
(E85),
aircraft
fuel
(AVGAS)
Liquid
dynamic
viscosity
range
[mPa.s]
0,5
to
10
Filtration
of
mechanical
particles
Pump
inlet
filter
>
100
μ
m;
pump
outlet
filter
>
70
μ
m
Fluid
temperature
range
[°C]
‐
20°
to
+50
**
Ambient
temperature
range
[°C]
‐
20
to
+40
(standard
dispenser
version);
‐
40
to
+55
(special
dispenser
version)
Accuracy
class
0.5
Mechanical
class
M1,
M2
for
counters
PDEX5
and
TBELTx
Electromagnetic
class
E1,
E2
for
the
counter
PDEX5
Humidity
Condensing
Location
Open
Measured
unit
Volume
[L]
or
volume
at
15
°C
[L]
Electronic
counter
TBELTx
PDEX
PDEX5
Program
version
(W&M
check
sum)
1.01
(8CA4)
1.03
(20260)
1.01
(4573),
1.02
(dbd2FFA4)
Calculator
powering
230V
±
10
%;
50Hz;
max.
300VA
Pump
electric
motor
3x400V/230V;
50Hz;
0.75kW;
1410
rpm
Electro
‐
magnetic
valves
Proportional;
+24V
DC/max.
1A
*
Flow
rate
range
Q
max
:
Q
min
must
be
10:1
**
Data
transmission
of
the
entire
contents
of
the
display
with
the
number
of
digits
7/6.5/5
is
only
possible
using
the
extended
communication
protocol
(8/8/6)
***
The
temperature
range
of
the
liquid
is
defined
by
the
range
of
the
measuring
temperature
sensor
Table
9
‐
LPG
(liquefied
propane
butane)
dispensers
and
modules
Maximum
flow
rate
Q
max
[L/min]
30
to
50
Minimum
flow
rate
Q
min
[L/min]
5
Lowest
metering
MMQ
[L]
5
Maximum
pressure
[MPa]
1.8
Minimum
pressure
[MPa]
0.7
Maximum
unit
price
(number
of
digits)
9999(4)
or
99999(5)
*
Maximum
amount
to
pay
(number
of
digits)
999999(6)
or
9999999(7)
*
Maximum
volume
(number
of
digits)
999999(6)
or
1999999(6.5)
*
Scale
interval
[L]
0.01
Display
type
Electronic
Type
of
delivered
fluid
LPG
(liquefied
propane
‐
butane)
Filtration
of
mechanical
particles
Input
filter
>25µm
Fluid
temperature
range
[°C]
‐
20
to
+40
Ambient
temperature
range
[°C]
‐
20
to
+40
Accuracy
class
1.0
Mechanical
class
M1,
M2
for
counters
PDEX5
and
TBELTx
Electromagnetic
class
E1,
E2
for
the
counter
PDEX5
Humidity
Condensing
Location
Open
Measured
unit
Volume
[L]
or
volume
at
15
°C
[L]
Electronic
counter
TBELTx
PDEX
TBELTM
PDEX5
Program
version
(W&M
check
sum)
1.01
(8CA4)
1.03
(20260)
1.01
(4092)
1.01
(4573),
1.02
(dbd2FFA4)
Calculator
powering
230V
±
10%;
50Hz;
max.
300VA
Electro
‐
magnetic
valves
Proportional
or
two
‐
state;
+
24VDC
/
max.1A
*
Data
transmission
of
the
entire
contents
of
the
display
with
the
number
of
digits
7/6.5/5
is
only
possible
using
the
extended
communication
protocol