166
Code
of
message
Type
of
message
Cause
of
error
message
Removing
error
message
E31
NFAT
Pulse
generator
channel
error
at
input
PDEX5
‐
PUL1
(PDEX
‐
1A)
Raise
and
hang
up
the
delivery
nozzle
several
times.
Turn
the
power
supply
of
the
dispenser
off
and
on.
If
the
fault
persists,
call
an
authorized
service
centre.
E32
NFAT
Pulse
generator
channel
error
at
input
PDEX5
–
PUL2
(PDEX
‐
2A)
E33
NFAT
Pulse
generator
channel
error
at
input
PDEX5
–
PUL3
(PDEX
‐
3A)
E34
NFAT
Pulse
generator
channel
error
at
input
PDEX5
–
PUL4
(PDEX
‐
4A)
E35
NFAT
Pulse
generator
channel
error
at
input
PDEX5
–
PUL5
(PDEX
‐
5A/1B)
E36
NFAT
Pulse
generator
channel
error
at
input
PDEX5
–
PUL6
(PDEX
‐
6A/2B)
E37
NFAT
Pulse
generator
channel
error
at
input
PDEX5
–
PUL7
(PDEX
–
7A/3B)
E38
NFAT
Pulse
generator
channel
error
at
input
PDEX5
–
PUL8
(PDEX
‐
8A/4B)
E39
NFAT
Pulse
generator
channel
error
at
input
PDEX5
–
PUL9
E40
NFAT
Pulse
generator
channel
error
at
input
PDEX5
–
PUL10
E41
NFAT
Connection
error
or
internal
pulse
generator
error
at
input
PDEX5
‐
PUL1
(PDEX
‐
1A)
Raise
and
hang
up
the
delivery
nozzle
several
times.
Turn
the
power
supply
of
the
dispenser
off
and
on.
If
the
fault
persists,
call
an
authorized
service
centre.
E42
NFAT
Connection
error
or
internal
pulse
generator
error
at
input
PDEX5
–
PUL2
(PDEX
‐
2A)
E43
NFAT
Connection
error
or
internal
pulse
generator
error
at
input
PDEX5
–
PUL3
(PDEX
‐
3A)
E44
NFAT
Connection
error
or
internal
pulse
generator
error
at
input
PDEX5
–
PUL4
(PDEX
‐
4A)
E45
NFAT
Connection
error
or
internal
pulse
generator
error
at
input
PDEX5
–
PUL5
(PDEX
‐
5A/1B)
E46
NFAT
Connection
error
or
internal
pulse
generator
error
at
input
PDEX5
–
PUL6
(PDEX
‐
6A/2B)
E47
NFAT
Connection
error
or
internal
pulse
generator
error
at
input
PDEX5
–
PUL7
(PDEX
–
7A/3B)
E48
NFAT
Connection
error
or
internal
pulse
generator
error
at
input
PDEX5
–
PUL8
(PDEX
‐
8A/4B)
E49
NFAT
Connection
error
or
internal
pulse
generator
error
at
input
PDEX5
–
PUL9
E50
NFAT
Connection
error
or
internal
pulse
generator
error
at
input
PDEX5
–
PUL10
E51
NFAT
Too
much
air
in
the
petrol
fuel
or
insufficient
LPG
pressure
difference
Petrol:
The
air
flow
sensor
on
the
output
of
pump
air
separator
has
been
active
for
longer
than
specified
by
parameter
M10
‐
P03.
LPG:
The
LPG
pressure
difference
was
less
than
1
bar
for
longer
than
specified
by
parameter
M10
‐
P03.
E51
‐
1
Main
pump
aeration
or
low
pressure
LPG
difference
(between
gas
and
liquid
phase>
1bar)
E51
‐
2
Auxiliary
pump
aeration
Petrol:
Check
the
intake
manifold
for
leaks.
LPG:
Check
the
pressure
in
the
supply
line
and
the
pressure
in
the
return
line
of
the
gas
phase
discharge
and
the
permeability
of
the
line.
Check
the
setting
of
the
TRAFAG
differential
pressure
switch
or
on
connected
pressure
sensors.