Fuel
Dispensers
TATSUNO
EUROPE
‐
Installation
and
User
Manual
,
revision
10,
January
2022
155
CAUTION
‐
>LPG
Any
handling
and
dismantling,
even
opening
the
filter
cap,
is
conditioned
by
extracting
the
medium
with
nitrogen
or
inert
gas
from
the
hydraulic
system
of
the
dispenser!
The
interventions
into
electrical
and
electronic
parts
may
only
be
performed
by
a
specialist
who
is
responsible
for
device
safety.
The
wires
must
be
repositioned
to
their
original
position
after
finishing
the
service
intervention.
Proper
fitting
of
wires
must
prevent
contact
with
the
movable
parts
of
the
reel
module.
Caution!
Tightness
of
hydraulic
sections
must
be
visually
inspected
in
every
service
intervention
and
possible
medium
leaks
must
be
removed.
THE
OPERATOR
OF
THE
DISPENSER
IS
OBLIGED
TO:
Appoint
an
employee
responsible
for
the
operation
and
technical
condition
of
the
dispenser.
Ensure
inspections,
testing,
repairs,
and
maintenance
in
a
professional
way.
Register
documents
and
keep
records
on
operation.
All
activities
related
to
attending,
operation
and
servicing
the
LPG
dispensing
module
may
only
be
performed
by
employees
with
appropriate
authorization.
PRINCIPLES
OF
LPG
DISPENSING
MODULE
INSPECTIONS
Inspections
of
devices,
reservoirs,
pipeline
systems
and
dispensers
are
performed
on
dates
defined
by
the
operating
rules
and
regulations
of
the
fuel
station
according
to
applicable
regulations.
Review
of
the
LPG
dispensing
module
hydraulic
system
tightness
by
soap
solution.
Review
of
the
machinery.
Review
of
the
check
and
safety
valve
functioning.
The
inspection,
calibration
and
official
verification
of
the
LPG
dispenser
is
performed
by
the
National
Metrology
Institute
according
to
applicable
regulations
The
inspection
is
preceded
by
cleaning
the
entire
device
from
dust,
removal
of
water
and
other
impurities
from
tanks.
PRINCIPLES
OF
CNG
DISPENSER
INSPECTIONS
Inspections
of
devices,
reservoirs,
pipeline
systems
and
dispensers
are
performed
on
dates
defined
by
the
operating
rules
and
regulations
of
the
fuel
station
according
to
applicable
regulations.
Review
of
dispenser
pressure
system
tightness
by
soap
solution.
The
inspection,
calibration,
and
official
verification
of
the
CNG
dispenser
is
performed
by
the
National
Metrology
Institute
according
to
applicable
regulations
The
inspection
is
preceded
by
cleaning
the
entire
device
from
dust,
removal
of
water
and
other
impurities
from
tanks.