3M CFS1254 Installation And Operation Instructions Manual Download Page 1

Description:

Base File Name:

Software:
SGS Contact:
Email:
Printer:
Printer Location:
Supplier:

3M Water Softeners

CFS1254 Installation and

Requester:

Michelle Miller

Reference:

Die # / Doc. Size:

8.5 x 11

Item Spec#:

34-8726-8629-9

Supersedes#:

Cat/Product#:

CFS1254

Structure#:

SS-55893

Operating Instructions

PA: 34872686299.indd
GA:

InDesign CC 2020

PROCESS

BLACK

6282874-2

1

02.24.21 Version 2. Add 2nd bullet under “To reduce the risk associated with the ingestion of contaminants:”

kat

PROCESS

CYAN

3M

Water Filtration Products

Installation and Operation Instructions for

CFS1254 Water Softeners

Installer: Please leave this manual with owner/operator.
Owner/Operator: Please retain for operation and future instructions.

Summary of Contents for CFS1254

Page 1: ... Filtration Products Installation and Operation Instructions for CFS1254 Water Softeners Installer Please leave this manual with owner operator Owner Operator Please retain for operation and future instructions ...

Page 2: ...NOTES ...

Page 3: ...and filter media To request an MSDS relating to the media shipped with this product call 203 238 8965 or go to www 3M com select country and use the search engine to search MSDS For emergencies call 800 364 3577 or 651 737 6501 24 hours CAUTION To reduce the risk associated with property damage due to water leakage Read and follow Use instructions before installation and use of this water treatmen...

Page 4: ...dia from entering valve and being discharged downstream Make Sure Your Water Has Been Thoroughly Tested An analysis of your water should be made prior to the selection of your water softener You can typically get this service through your place of purchase which may require sending a sample to the factory for analysis and recommendations Enter your analysis below for your permanent record Analysis...

Page 5: ...ection 7 IMPORTANT NOTES If sediment is present the installation of a sediment pre filter is recommended Even if sediment is not currently present or at a level high enough to be objectionable a pre filter can help increase the efficiency of the softener and help reduce the amount of maintenance required Installation Site Selection Select the location of your water softener with care Various condi...

Page 6: ...oducts will vary depending on the control valve brand used 3 Before beginning the installation review the existing piping system and to determine the size number and type of fittings required WARNING To reduce the risk associated with a hazardous voltage If the electrical system requires use of the cold water system as an electrical safety ground a jumper must be used to ensure a sufficient ground...

Page 7: ...f control valve Water flow should match arrow on control valve The Inlet and Outlet of other water treatment equipment products will vary depending on the control valve brand used BRINE TANK WATER SOFTENER FILTER OPTIONAL SOFT WATER TANK SWITCH PRESSURE PRESSURE WATER RAW METER UTILITY WATER OR OTHER LAWN SPRINKLERS WATER FOR WELL WATER RAW CHECK VALVE FILTERED WATER FILTERED SOFT WATER FILTERED W...

Page 8: ...ply heat to any plastic part when making the connection of the plumbing to the connection fittings Utilize only thread sealant tape to seal any NPT fittings that connect to the connection fittings Both NPT connections utilize an o ring to prevent a leak Next connect the connection fittings to the bypass valve attached to the control valve Be cautious not to over tighten the fittings as damage to t...

Page 9: ...the retaining clip from the brine line fitting on the control valve The retaining clip is holding a plastic insert sleeve and needs to be inserted into the polyethylene tubing before installing the tub ing into the fitting elbow and hand tighten only CAUTION DO NOT use pliers or wrenches to tighten as damage may occur and will void the manufacturer s warranty Step 10 Install the overflow line to t...

Page 10: ...will not completely fill with water Unit is ready for service when the Time shows on the display Time of Day will be on the display Step 17 Fill brine tank with salt Step 18 Refer to Section 3 Control Valve Programming and Regenera tion Instructions on how to set control valve for proper set up and regeneration settings SPECIAL SERVICE INSTRUCTIONS Under normal circumstances removal of the valve s...

Page 11: ...n to previous step Step 4 Next Regeneration Time hour Set the hour of day for regeneration using or buttons AM PM toggles after 12 The default time is 2 00 a m Press NEXT to go to Step 5 Press REGEN to return to previous step Step 5 Next Regeneration Time minutes Set the minutes of day for regeneration using or buttons Press NEXT to exit Installer Display Settings Press REGEN to return to previous...

Page 12: ...meter is not installed Press the NEXT button Press REGEN to return to previous step Step 7 Flow rate maximum last seven days The maximum flow rate in gallons per minute that oc curred in the last seven days will be displayed This display will equal zero if a water meter is not in stalled Press the NEXT button Press REGEN to return to previous step Step 8 Gallons total used since last reset The tot...

Page 13: ...tep Step 4 Gallons total used since start up This display shows the total gallons This display shows the total days since start up Press the NEXT button to go to the next step Press REGEN to return to previous step Step 5 Days total since start up This display shows the total days since start up Press the NEXT button to go to the next step Press REGEN to return to previous step Step 6 Regeneration...

Page 14: ...ancel the request To initiate a manual regeneration immediately press and hold the REGEN button for 3 seconds The system will begin to regenerate im mediately The request cannot be cancelled NOTE For water softeners if brine tank does not contain salt fill with salt and wait at least two hours before regenerating Set Time of Day The user can also set the time of day Time should only need to be set...

Page 15: ...media bed will eventually become iron fouled resulting in reduced softening capacity and rust stained fixtures Mixing one to two ounces of Iron Reduction Media with every 80 lbs 36 kg of salt added to brine tank will help minimize these problems from occurring Please contact your Dealer Installer or our Customer Service Department at 1 866 990 9785 for additional information Periodically Check Tim...

Page 16: ...3 seconds B Foreign matter is lodged in control valve B Check piston and spacer stack assembly C High drive forces on piston C Replace piston s and spacer stack assembly D Control valve piston not in home position seconds D Press NEXT and REGEN for 3 seconds or unplug power source jack black wire and plug back in to reset control valve E Motor not inserted fully to engage pinion motor wires broken...

Page 17: ...est of the three clips is always orientated to the bottom of the drive bracket With the PC board facing up push in and down on the large clip on the drive gear cover Handle the cover and the gears carefully so that the gears do not fall off of the pegs in the cover Replace broken or damaged drive gears Do not lubricate any of the gears Avoid getting any foreign matter on the reflective coating bec...

Page 18: ...k assembly in The control valve body bore interior can be lubricated with silicone to allow for easy insertion of the entire stack Do not use silicone or any other type of lubricant on the clear lip seals of the piston Reattach the drive cap assembly and piston s and the drive assembly After completing any valve maintenance press and hold NEXT and REGEN buttons for 3 seconds or unplug power source...

Page 19: ...he black o ring Snap the turbine on the shaft and reinsert the water meter into the side slot Hand tighten the nut Do not use a pipe wrench to tighten nut Bypass Valve The working parts of the bypass valve are the rotor assemblies that are contained under the bypass valve caps Before working on the rotors make sure the system is depressurized Turn the red arrow shaped handles towards the center of...

Page 20: ...es at wrong time of day A Timer improperly set A Reset timer 5 Water continuously flows to drain A Foreign material in control valve A Remove piston assembly and inspect bore remove foreign material and check control in various regeneration positions B Internal control leak B Replace seals and or piston assembly C Control valve jammed in brine or backwash position C Replace piston seals and spacer...

Page 21: ...x 15 x 34 Brine Tank Capacity With Salt Grid Leg Extensions required on salt settings above 18 135 Approximate Shipping Wt 188 Maximum Operating Temperature 110 F 43 3 C Minimum Operating Temperature 34 F 1 C Operating Pressure 20 125 psi 138 862 kPa Electrical Requirements 110 120V 60Hz The CFSM1254 softener conforms to NSF ANSI Standard 44 for specific performance claims Actual capacity may vary...

Page 22: ...BT15GP EXT 12 Safety Brine Valve Complete BT15SBVA 13 Safety Brine Valve 60014 14 Float Assembly 60068X 15 Air Check 60002 27 5 NOTE When ordering replacement or repair components always specify by the unit or model number to ensure correct parts delivered Items Not Shown Description of Item Part Number Wrench V3193 01 Universal Elbow V3191 01 Retaining Clip H4615 Drain Line Insert PKP10TS8 BULK D...

Page 23: ...tity 1 V1375 01 WS1 Front Cover 1 2 V3107 01 WS1 Motor 1 3 V3106 01 WS 1 Drive Bracket Spring Clip 1 4 V3108 WS1 PC Board 1 V3002 WS1 Drive Assy 1 Not Shown V3168 WS1 AS Adapter 110V 12 V 1 Not Shown V3168 01 WS1 AC Adapter Cord Only 1 Drawing number parts 2 through 6 may be purchased as a complete assembly part V3002 ...

Page 24: ...bly Drawing No Order No Description Quantity 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assembly 1 3 V3178 Drive Back Plate 1 4 V3011 Piston Down Flow Assembly 1 5 V3174 Regenerant Piston 1 6 V3135 O ring 228 1 7 V3180 O ring 337 1 8 V3105 O ring 215 Distributor Tube 1 Not Shown V3001 Body Assembly 1 2 4b 6 5 1 7 3 8 4 ...

Page 25: ...ector Cap 1 2 V3152 O ring 135 1 3 V3177 01 Injector Screen 1 4 V3010 1Z Injector Assy Z Plug 1 5 V3010 1B INJECTOR ASSY B BROWN V3010 1C INJECTOR ASSY C VIOLET V3010 1E INJECTOR ASSY E WHITE V3010 1H INJECTOR ASSY H GREEN Not Shown V3170 O ring 011 Not Shown V3171 O ring 013 The injector plug and the injector each contain one 011 lower and 013 upper o ring ...

Page 26: ...ytube insert 3 8 1 3 JCPG 6PBLK Nut 3 8 1 4 H4613 Elbow Cap 3 8 1 5 V3163 O ring 019 1 6 V3165 01 BLFC Retainer Assembly 1 7 V3182 BLFC 1 Not Shown H4650 Elbow 1 2 with nut and insert Option Assembly includes V3182 BLFC Includes drawing 7 Water Flow Proper BLFC orientation towards the washer face with rounded edge and text 1 2 3 4 5 6 7 directs refill water flow ...

Page 27: ...2 Nut 3 4 Drain Elbow 1 4 V3158 01 Drain Elbow 3 4 Male 1 5 V3163 O ring 019 1 6 V3159 01 DLFC Retainer Assembly 1 7 V3162 013 DLFC 1 3 gpm for 3 4 One DLFC must be used if 3 4 fitting is used V3162 017 DLFC 1 7 gpm for 3 4 V3162 027 DLFC 2 7 gpm for 3 4 V3162 053 DLFC 5 3 gpm for 3 4 Water Flow Proper DLFC orientation directs water flow towards the washer face with rounded edge ...

Page 28: ...PONENT PARTS LIST Water Meter and Meter Plug Drawing No Order No Description Quantity 1 V3151 Nut 1 QC 1 2 V3003 Meter Assembly includes drawing 3 4 1 3 V3118 01 Turbine 1 4 V3105 O ring 215 1 5 V3003 01 Meter Plug Assembly 1 3 4 5 1 2 ...

Page 29: ... 1 4 V3 Fitting 3 4 Brass Sweat Assembly 1 Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 1 2 V3150 Split Ring 1 3 V3105 O ring 215 1 4 V3317 Fitting 1 1 4 Plastic Male NPT 1 Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 1 2 V3150 Split Ring 1 3 V3105 O ring 215 1 4 V3164 Fitting 1 Plastic Male NPT 1 Order No V3007 03 Description Fitting 3 4 Brass Sweat...

Page 30: ... ring 215 2 4 V3145 Bypass 1 Rotor 2 5 V3146 Bypass Cap 2 6 V3147 Bypass Handle 2 7 V3148 Bypass Rotor Seal Retainer 2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 V3191 01 Vertical Adapter Assembly Order No Description Quantity V3151 Nut 1 Quick Connect 2 V3150 Split Ring 2 V3105 O ring 215 2 V3191 Vertical Adapter 2 6 5 6 5 4 1 4 1 1 2 3 3 1 2 ...

Page 31: ...IST Wrench Order No V3193 01 Although no tools are necessary to assembly or disassemble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Loosens Injector And Bypass Caps Loosens Drive Cap ...

Page 32: ...efund the purchase price of the Product This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purification Inc s exclusive obligation Warranty Period One 1 year on the entire product unit Five 5 years on the media tank only does not include internal component parts Five 5 years on the control valve Five 5 years on salt storage container and compone...

Reviews: