TATSUNO
EUROPE
a.s.,
www.tatsuno
‐
europe.com
22
Table
3
–
Gasoline,
(bio)diesel,
E85,
kerosene
and
aircraft
fuel
dispensing
and
measuring
equipment
(AVGAS)
#
Device
type
Marking
Manufact
urer
ATEX
certificate
MID
certificate
Note
1
Pumping
monoblock,
Q
max
50
L/min.
FP
‐
1001
‐
B01
TATSUNO
FTZÚ13ATEX0168X
TCM141/07
‐
4491
pump
+
separator
2
Pumping
monoblock,
Q
max
90
L/min.
FP
‐
1001
‐
B02
TATSUNO
FTZÚ13ATEX0168X
TCM141/07
‐
4491
pump
+
separator
3
Pumping
monoblock,
Q
max
90
L/min.
FP
‐
1022
TATSUNO
FTZÚ10ATEX0257X
ZR141/11
‐
0080
pump
+
separator
4
Piston
meter,
Q
max
90
L/min.
FM
‐
1007
TATSUNO
FTZÚ03ATEX0022
*
TCM141/07
‐
4491
5
Piston
meter,
Q
max
90
L/min.
FM
‐
1025
TATSUNO
FTZÚ10ATEX0258X
ZR141/11
‐
0080
6
Meter
LOBE
Ø32,
Q
max
200
L/min.
FF
‐
1006
TATSUNO
FTZÚ11ATEX0108X
ZR141/11
‐
0082
7
Meter
LOBE
Ø52,
Q
max
400
L/min.
FF
‐
1002
TATSUNO
FTZÚ14ATEX0054
‐
8
Meter
LOBE
Ø82,
Q
max
1000
L/min.
FF
‐
1004
TATSUNO
FTZÚ14ATEX0054
ZR141/14
‐
0112
9
Pulse
generator,
optoelectronic
EK
‐
1025
TATSUNO
FTZÚ04ATEX0094X
TCM141/07
‐
4491
part
of
the
meter
4,
Ex
d
design
10
Pulse
generator,
magnetic
ZE
‐
1945
TATSUNO
FTZÚ06ATEX0292X
ZR141/11
‐
0080
part
of
meters
5,6,7,8;
Ex
m
design
11
Pulse
generator,
magnetic
EK
‐
1129
TATSUNO
FTZÚ16ATEX0132X
TCM141/07
‐
4491
part
of
the
meter
5;
Ex
d
design
12
Electronic
counter
PDEX
TE
‐
TCM141/07
‐
4491
all
types
of
dispensers
13
Electronic
counter
PDEX5
TE
‐
ZR141/18
‐
0175
all
types
of
dispensers
14
Electronic
counter
TBELTx
TE
‐
TCM141/07
‐
4491
all
types
of
dispensers
LPG
dispensers
and
modules
are
equipped
with
TATSUNO
hydraulics
with
high
reliability
and
long
service
life.
The
two
‐
channel
TATSUNO
pulse
generator
is
mounted
on
a
piston
meter
or
it
is
its
integral
part.
The
measuring
unit
consists
of
a
piston
meter,
a
filter,
a
separator,
a
liquid
phase
check
valve,
and
a
gaseous
phase
safety
valve.
The
safety
valve
is
adjusted
to
a
pressure
of
1.8
MPa
and
prevents
the
maximum
operating
pressure
from
being
exceeded
by
discharging
the
liquid
phase
back
into
the
storage
tank.
An
electronic
differential
pressure
sensor
(formerly
TATSUNO
differential
valve)
is
mounted
at
the
output
of
the
meter
to
check
the
pressure
difference
between
the
liquid
medium
and
its
gaseous
phase.
In
case
of
insufficient
pressure
difference
(<1
bar),
the
pumping
of
the
medium
is
terminated
to
avoid
inaccurate
measurement
due
to
the
presence
of
the
gaseous
phase
in
the
meter.
The
pumped
medium
(LPG)
is
supplied
by
a
pump
located
outside
the
dispenser
space,
flows
through
the
inlet
safety
solenoid
valve
(if
installed)
then
through
the
G¾”
shut
‐
off
ball
valve
through
the
particulate
filter
25
μ
m
into
the
separator.
If
the
liquid
contains
the
gaseous
components,
these
are
separated
and
returned
to
the
storage
tank
from
the
top
of
the
separator
by
a
return
pipeline
which
must
be
opened
(ball
valve
at
the
inlet
G
½")
if
the
dispensing
module
is
in
operation.
Reverse
piping
inside
diameter
must
be
at
least
DN
16.
From
the
separator,
the
liquid
flows
through
the
check
valve
to
the
piston
meter
and
flows
through
the
solenoid
valve
controlling
the
flow
of
the
medium
(if
installed),
the
sight
hole
and
the
breakaway
coupling
into
the
delivery
hose
and
through
the
delivery
nozzle
it
is
transported
to
the
vehicle
storage
tank.
The
filling
pressure
can
be
monitored
on
a
manometer
located
under
the
delivery
nozzle
hanger.