Fuel
Dispensers
TATSUNO
EUROPE
‐
Installation
and
User
Manual
,
revision
10,
January
2022
137
Endress
Hauser
CNGmass
m.
factor
volume
flow
according
parameter
P44
m.
offset
mass
flow
0
m.
offset
volume
flow
0
m.
factor
density
1
m.
offset
density
0
m.
factor
temperature
1
m.
offset
temperature
0
Assign
low
flow
cut
off
mass
flow
On
value
low
flow
cut
off
0,055
kg/min
Flow
dumping
0
s
Auto
scan
buffer
Addresses
registers
in
order:
‐
mass
flow
‐
volume
flow
‐
density
‐
temperature
‐
totalizer
#1
sum
‐
totalizer
#1
overflow
‐
totalizer
#2
sum
‐
totalizer
#2
overflow
Zero
‐
point
Note:
This
value
is
stored
after
zero
‐
point
adjustment
procedure,
see
later.
Serial
number
Number
stored
during
Serial
number
storage
procedure
NOTICE
‐
CNG
After
start
‐
up
of
calculator
TBELTM
and
before
every
delivery
transaction
are
checked
values
of
the
registers
inside
mass
meter
if
they
are
equal
with
values
saved
in
calculator
memory.
If
not,
error
code
E74
is
appeared
on
display
and
delivery
is
not
allowed.
To
disable
the
error
is
necessary
to
perform
function
P99
=
4444
again.
NOTICE
‐
CNG
To
run
function
mass
meter
configuration
is
necessary
to
press
<R>
on
yellow
service
remote
transmitter
PDERT
‐
5S,
enter
service
password
(factory
setting
11111111)
followed
by
key
<E>.
In
Service
mode
of
calculator
is
necessary
to
press
99
with
<E>
to
go
on
parameter
99
and
after
press
<E>
again,
enter
value
4444
and
<E>.
If
function
passed
OK
then
message
„done
“appeared
for
a