4.1.13.
SERIAL
NUMBERS
OF
THE
PERIPHERAL
UNITS
(P10)
The
parameter
is
used
to
display
the
serial
numbers
of
the
connected
peripheral
units.
The
actual
serial
numbers
of
the
peripheral
units
are
compared
with
the
numbers
stored
in
the
processor
unit
memory.
If
a
mismatch
is
detected,
an
error
message
is
displayed
and
fuel
delivery
is
not
allowed.
The
list
of
periphearal
units
is
below.
Example:
Parameter
P10
‐
1,
serial
number
of
the
main
processor
unit
SN:
18
‐
00101
(see
picture)
Parameter
Peripheral
unit
Error
message
in
case
of
detected
mismatch
P10
‐
1
Main
processor
unit
P10
‐
2
Main
temperature
sensors
unit
PDEINP1
(for
temp.
sensors
1
to
4)
E83
‐
1
P10
‐
3
Auxiliar
temperature
sensors
unit
PDEINP2
(for
temp.
sensors
5
to
8)
E83
‐
2
P10
‐
4
Mass
meter
A
E84
‐
1
P10
‐
5
Mass
meter
B
E84
‐
2
P10
‐
6
Main
displaying
unit
(Master)
of
filling
point
A
E80
‐
1
P10
‐
7
Auxiliar
displaying
unit
(Slave)
of
filling
point
A
E80
‐
2
P10
‐
8
Main
electromechanical
totalizers
unit
(Master)
of
filling
point
A
E82
‐
1
P10
‐
9
Auxiliar
electromechanical
totalizers
unit
(Slave)
of
filling
point
A
E82
‐
2
P10
‐
10
Main
displaying
unit
(Master)
of
filling
point
B
E80
‐
1
P10
‐
11
Auxiliar
displaying
unit
(Slave)
of
filling
point
B
E80
‐
2
P10
‐
12
Main
electromechanical
totalizers
unit
(Master)
of
filling
point
B
E82
‐
1
P10
‐
13
Auxiliar
electromechanical
totalizers
unit
(Slave)
of
filling
point
B
E82
‐
2
P10
‐
14
Main
displaying
unit
(Master)
of
filling
point
C
E80
‐
1
P10
‐
15
Auxiliar
displaying
unit
(Slave)
of
filling
point
C
E80
‐
2
P10
‐
16
Main
electromechanical
totalizers
unit
(Master)
of
filling
point
C
E82
‐
1
P10
‐
17
Auxiliar
electromechanical
totalizers
unit
(Slave)
of
filling
point
C
E82
‐
2
P10
‐
18
Main
displaying
unit
(Master)
of
filling
point
D
E80
‐
1
P10
‐
19
Auxiliar
displaying
unit
(Slave)
of
filling
point
D
E80
‐
2
P10
‐
20
Main
electromechanical
totalizers
unit
(Master)
of
filling
point
D
E82
‐
1
P10
‐
21
Auxiliar
electromechanical
totalizers
unit
(Slave)
of
filling
point
D
E82
‐
2
P10
‐
22
Pressure
sensors
unit
PDEDPS
with
address
1
E85
P10
‐
23
Pressure
sensors
unit
PDEDPS
with
address
2
E85
P10
‐
24
Pressure
sensors
unit
PDEDPS
with
address
3
E85
P10
‐
25
Pressure
sensors
unit
PDEDPS
with
address
4
E85
4.1.14.
VAPOUR
RECOVERY
USER
TEST
DURATION
–
DRY
TEST
(P11)
The
parameter
specifies
the
test
duration
in
seconds
for
which
the
vapour
recovery
system
vacuum
pump
will
start
after
pressing
the
<8>
button.
The
setting
is
made
by
pressing
the
<E>
key
by
entering
the
test
time
in
<SSS>
format
and
confirming
with
the
<E>
key.
Parameter
Meaning
Factory
setting
P11
=
5,
6…300
Dry
Test
duration
in
seconds
60
seconds
Sn
1
800101
P10
‐
1
M0
60
P11