When the actual remaining
amount inside the pail is less
than the remaining amount on
the screen
If you proceed with the pail
replacement work as soon as
the follower plate passes the
top of the pail.
Pail replacement refer to the contents and proceed
with the pail replacement procedure
Level sensor undetectable
phenomenon
(Undetected / fixed part
undetected due to mechanical
error between rack for
remaining amount
measurement and contact
sensor position)
Rack and contact sensor position
Pail when the actual remaining
amount is exhausted, but the
remaining amount on the
screen is displayed at 100%
Suspected level sensor failure
Level sensor needs to be replaced.
When the pressure does not
rise even after a certain period
of time has passed during the
run operation after combining
with pail
When joining the pail internal
material when it is not flat, the
material reaches the vent valve
first and the bonding ends,
leaving an empty space inside.
Proceed to the bubble removal work.
Pay attention to the flatness of the inner material of
the pail when joining in the future.
When an alarm occurs during
automatic coupling
Change vent tube alarm
generated
1. Liquid removal from Vent sensor
2. Check the setting of HMI ETC Page vent contact
"NC"