6.5
Pail replacement
6.5.1
Auto mode
When replacing the pail in auto mode, pressing the change button on the front panel will execute the
sequence in which the plate is removed from the pail, and the explanation for this sequence is as
follows.
When you touch change in auto mode, it is divided into three operation sequences as follows.
Act1. When the cylinder position is greater than the blower high value.
Act2. When the cylinder position is less than or equal to the blower high value
Act3. When the cylinder high limit sensor is on.
When you touch the change button, as shown in Act1 on the left, the blower is always on, and the
cylinder up repeatedly turns on/off to raise the follow plate.