PRO CAN PUMP DUAL (PRO-CPD20)
Rev 1.6
2023/07/31
48/95
Copyright
©
2023 by TAEHA CORP. All Rights Reserved
HIGH PRE.
Setting the top pressure limit
➔
Set the top limit of control pressure to prevent excessive
supply pressure.
➔
The alarm and pump will stop when the pressure rises.
➔
The top limit detection position of pressure varies depending
on the reference sensor.
The top limit detection position of pressure depending on
reference sensor setting
➔
P1 : Detect the top pressure limit of plate supply pressure
unit.
➔
P2 : Detect the top limit of the dispensing unit.
➔
P2 : Detect the top limit of the dispensing unit.
LOW PRE.
Setting the bottom limit of pressure
➔
Set the bottom limit of pressure to detect if the supply is not
smooth because the supply pressure drops to the bottom
limit during normal operation.
➔
The alarm and pump stop when the bottom limit of pressure
is maintained for a certain time.
The top limit detection position of pressure depending on
reference sensor setting
➔
P1 : Detect the top pressure limit of plate supply pressure
unit.
➔
P2 : Detect the top limit of the dispensing unit.
➔
P2 : Detect the top limit of the dispensing unit.
Maximum pressure set-up
➔
Set maximum pressure value of P1 materials transfer when
reference sensor P1 + P2 is linked.
➔
Activated when P1 + P2 is used.