![TAEHA PRO CAN PUMP DUAL User Manual Download Page 33](http://html2.mh-extra.com/html/taeha/pro-can-pump-dual/pro-can-pump-dual_user-manual_4987184033.webp)
PRO CAN PUMP DUAL (PRO-CPD20)
Rev 1.6
2023/07/31
33/95
Copyright
©
2023 by TAEHA CORP. All Rights Reserved
6.2.1
Pail high setting
Raise the cylinder on the manual operation screen to reach the cylinder top sensor.
When the cylinder top sensor is reached, rising cylinder stops and the cylinder position value becomes
zero.
Lower cylinder operation pressure to minimum (150 ~ 200kPa) to minimize cylinder movement speed.
➔
If the cylinder minimum pressure is changed to the minimum, combine the container to be
used with the equipment.
➔
The cylinder position value increases when the cylinder is lowered, and the bottom of the
cylinder is made identical to the top of the container (cylinder lowering operation is required).
➔
Type the position value on the top value of the container.
Cylinder upper
limit sensor
Cylinder bottom side should be
aligned with PAIL’s top level.