6.2.2
Pail low setting
Raise the cylinder on the manual operation screen to reach the cylinder top sensor.
When the cylinder top sensor is reached, rising cylinder stops and the cylinder position value becomes
zero.
Lower cylinder operation pressure to minimum (150 ~ 200kPa) to minimize cylinder movement speed.
➔
If the cylinder minimum pressure is changed to the minimum, combine the container to be
used with the equipment.
➔
The cylinder position value increases when the cylinder is lowered, and the bottom of the
cylinder is made identical to the bottom of the container. (cylinder lowering operation is
required)
➔
Enter the position value on the bottom value of the container.
➔
At this time, it is possible to proceed without a container, but enter a numerical value of
about -5, taking into account the distance between the bottom of the container and the
bottom.