![Tadiran Telecom TGW4 SERIES User Configuration Manual Download Page 32](http://html1.mh-extra.com/html/tadiran-telecom/tgw4-series/tgw4-series_user-configuration-manual_813338032.webp)
User Configuration Manual TGW4/8 Gateway Series for Aeonix
20 Tadiran Telecom (TTL) L.P.
Name
Description
*
Proxy server
Configure the IP address and port number of the SIP proxy server. The address and port
number are separated by “:”. It has no default value.
The proxy server address can be set to an IP address or a domain name. e.g.
168.33.134.51:5000 or www.sipproxy.com:5000.
When a domain name is used, you must activate DNS service and configure DNS server
parameters on the network-configuration page.
When a domain name is used, you can fill in a backup IP address in
Backup SIP proxy
server
in the High Availability configuration. This allows the TGW to failover to the IP
address if the domain name resolution service fails.
For Aeonix
Enter the Aeonix server IP address or name
(ex. 172.28.1.260 or tdd.tad.com).
Subdomain
name
This domain name will be used in INVITE messages. If it is not set here, the gateways
will use the IP address or domain name of the proxy server as the user-agent domain
name. It has no default value.
*
Registrar mode
The gateway supports three registration schemes:
Per line
(default): authentication and register per line
Per gateway
: authentication and register per gateway
Per line/GW auth
: Enable registration per line. Use the number configuration per line.
Use the global account and password in authentication
For Aeonix
Select
Per line
*
User name
Configure the user name as part of the account for registration. It has no default value.
Note: If
Per gateway
or
Per line/GW Auth
is selected for
Registrar mode
, the user
name must be entered here. If
per line
is selected, the user name should be set on “Line >
on page 27).
For Aeonix
In the
User name
box, enter the Trunk user name.
Use Table 2-8 below as a worksheet to make a list of Trunk User Name/Password.
*
Registrar
password
Password as part of account information is used for authentication by platform. It has no
default value. It is formed with either numbers or characters, and is case sensitive.
Note: If
Per gateway
or
Per Line/GW Auth
is selected for
Registrar mode
, the
password must be entered here. If
Per line
is selected, the password should be set on
“Line > Feature” page (Refer to
on page 27).
For Aeonix
In the
Password
box, enter the Trunk password.
Use Table 2-8 below as a worksheet to make a list of Trunk User Name/Password.
Registration
expiration
Valid time of SIP re-registration in seconds. Its default value is 600 sec.
Table 2-8 below is used in section 3.3 FXO Trunk Line – Basic Configuration (TGW8-2G) on page 90.
Table 2-8
SIP Trunk User name / Password
Name
, above)
Trunk user name
Trunk password