![Tadiran Telecom TGW4 SERIES User Configuration Manual Download Page 113](http://html1.mh-extra.com/html/tadiran-telecom/tgw4-series/tgw4-series_user-configuration-manual_813338113.webp)
TGW4/8 Gateway Series for Aeonix High Availability Configuration Guide
Tadiran Telecom (TTL) L.P.
101
3.
Click the
Line > Advanced
tab.
For detailed information, see
Subscriber Line Characteristics
a)
For Aeonix US ALARMS:
- Adjust
Gain to IP
to 0 dB
- Adjust
Gain to terminal
to -1.5 dB
b)
In the
Hook flash time min
box, enter the required time as per actual phone type.
NOTE: Used by the gateway to detect Hookflash events (default is 75 ms). The gateway will
ignore any flash that falls short of the shortest flash time. Generally, this value should not be
less than 75 ms.
c)
For Aeonix US ALARMS:
- In the
Ring frequency
box, enter 20 (Hz)
d)
From the
Message waiting indication
drop-down list, select
High-voltage
.
e)
Click
Save
.