SV 971A User Manual
97
14.3.1
Instruments’ status screen
In the scanning/status screen you may observe the state of a set of instruments.
Each instrument status is displayed in the frame that contain up to tree fields. First field displays the
instrument name and serial number. Second field shows the instrument status (
Turned off
) or if it is
turned on
– the measurement status. If the measurement is stopped the field is red, if in progress it is
green, if in pause
– yellow.
The third field contains several icons that inform you about:
Internal
battery
status of the selected instrument. Battery capacity is displayed as
a percentage. When the battery is low, the icon turns red.
Internal
memory
status of the selected instrument. The green area and the
percentage display the empty memory capacity.
Dose
alarm
. If the dose exceeds the threshold level, the icon is red, and the mobile
device vibrates.
Movement
of a controlled person. If the controlled person is moving, the icon is
green, otherwise the icon is red (not used in SV971A instruments).
Someone is using the instrument
’s
keyboard
(not used in SV971A instruments).
Lockout
status due to different current device control over this instrument.
As an example:
-
The instrument SV 100A #44897 is switched off.
-
The instrument SV 100A #44897 is switched on and
measurement is stopped. Battery charging is 95%, free
memory is 99%, no alarm, the controlled person in not
driving a vehicle.
-
The instrument SV 104A #56400 is switched on and
measurement is running. Current Dose value is
displayed. The controlled person presses the
instrument’s button and this instrument is already
controlled by another mobile device. Note, that since
scanning there may be a few seconds’ delay.
Summary of Contents for SV 971A
Page 220: ...SV 971A User Manual Appendixes 220 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 221: ...SV 971A User Manual Appendixes 221 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 222: ...SV 971A User Manual Appendixes 222 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 223: ...SV 971A User Manual Appendixes 223 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 224: ...SV 971A User Manual Appendixes 224 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Page 232: ...SV 971A User Manual Appendixes 232 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 233: ...SV 971A User Manual Appendixes 233 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 234: ...SV 971A User Manual Appendixes 234 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 235: ...SV 971A User Manual Appendixes 235 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 236: ...SV 971A User Manual Appendixes 236 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Page 298: ...SV 971A User Manual Appendixes 298 O ring gasket locations inside...