![Svantek SV 971A User Manual Download Page 128](http://html1.mh-extra.com/html/svantek/sv-971a/sv-971a_user-manual_1409270128.webp)
SV 971A User Manual
128
Level
Threshold level of
Source
for triggering condition
fulfilment.
Chapter
Pre Trigger
Period of additional logging before triggering
condition fulfilment.
Chapter
Post Trigger
Period of additional logging after triggering
condition fulfilment.
Chapter
Wave
Recording
Recording of the waveform signal in the wave file.
Chapter
Recording
Switching on the signal recording:
Continuous
or
on trigger:
Slope+, Slope -, Level+, Level
–,
G,
Trigger Chapter
or
Integr. Period
.
Continuous means that the waveform signal will be
recorded continuously from the start of the
measurement till its end. On trigger recording put
additional conditions for triggering and ending of the
recording.
If the instrument is waiting for the trigger condition,
the appropriate trigger icon is flashing on the display
alternatively with the „signal” icon.
Chapter
Slope+
Type of trigger that starts the signal recording for
Recording Time
under the condition: rising value of
the LEQ result (
Source
) integrated during 0,5 ms
passes above the threshold level (
Level
).
Chapter
Slope -
Type of trigger that starts the signal recording for
Recording Time
under the condition: falling value of
the LEQ result (
Source
) integrated during 0,5 ms
passes below the threshold level (
Level
).
Chapter
Summary of Contents for SV 971A
Page 220: ...SV 971A User Manual Appendixes 220 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 221: ...SV 971A User Manual Appendixes 221 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 222: ...SV 971A User Manual Appendixes 222 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 223: ...SV 971A User Manual Appendixes 223 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 224: ...SV 971A User Manual Appendixes 224 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Page 232: ...SV 971A User Manual Appendixes 232 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 233: ...SV 971A User Manual Appendixes 233 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 234: ...SV 971A User Manual Appendixes 234 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 235: ...SV 971A User Manual Appendixes 235 5600 Hz 6300 Hz 7100 Hz 8000 Hz 8500 Hz 9000 Hz...
Page 236: ...SV 971A User Manual Appendixes 236 9500 Hz 10000 Hz 10600 Hz 11200 Hz 11800 Hz 12500 Hz...
Page 298: ...SV 971A User Manual Appendixes 298 O ring gasket locations inside...