Chapter 3: System Interface
3-3
3-3 Control Panel LEDs
The four control panels are located on the front handle of the SCF424AS chassis.
Each control panel has two additional LEDs. These LEDs provide you with critical
information related to different parts of the system. This section explains what each
LED indicates when illuminated and any corrective action you may need to take.
Information LED
See the following table for the status shown by this LED.
Information LED
Status
Description
Continously on and red
An overheat ocondition has occured. (This may be caused by cable congestion.)
Blinking red (1 Hz)
Fan failure: check for an inoperative fan.
Blinking red (0.25 Hz)
Power failure: check for an inoperative power supply.
Solid blue
Local UID has been activated. Use this function to locate the server in a rack
environment.
Blinking blue (300 msec)
Remote UID has been activated. Use this function to locate the server from a
remote location.
•
NIC: Indicates network activity on either LAN1 or LAN2 when fl ashing.