![SUPERLOLUX XMS-TYPH-R4-XX User Manual Download Page 44](http://html1.mh-extra.com/html/superlolux/xms-typh-r4-xx/xms-typh-r4-xx_user-manual_1403311044.webp)
NVR Software - SeeTec client
42
4.1.3
Client configuration
1. In the
File
menu, select
Client configuration
to change the client settings:
Only the SeeTec administrator can open
Client configuration
.
Important
The following settings must be configured for each client and for
each Windows
®
login profile.
Network tab
The
Timeout for server requests
option is used to increase request times in
Archive Mode
. Consequently, no timeout will occur and no red beam will be
displayed in the player when performing large requests in
Archive Mode
.
The UDP or TCP port for image transmission determines the protocol and the port
used to transmit image streams of the cameras from the SeeTec server to the
client.
If you use multiple independent SeeTec 5 systems, you can automatically connect
the client to a backup server on network failure.
1. Enable the
Automatically connect to backup server on network failure
option.
2. In the
Name
field, enter the name or the IP address of the backup server.
3. In the
Port
field, enter the port of the backup server.
4. Limit the
Bandwidth
when accessing servers with narrow-band connections.
First, double-click on the corresponding
CameraManagement
to select it.
5. In the following dialog, you can limit the maximum bandwidth using the
Max. bandwidth in kbit/s
field.