![SUPERLOLUX XMS-TYPH-R4-XX User Manual Download Page 33](http://html1.mh-extra.com/html/superlolux/xms-typh-r4-xx/xms-typh-r4-xx_user-manual_1403311033.webp)
NVR Software - Installation
31
Important
Should the connection to the administrative services be interrupted
and not restored immediately, all distributed servers are set to
emergency mode:
Standard recording of all cameras on the distributed server
continues.
The following restrictions apply for alarm recording:
For complex alarm scenarios, preconditions are not evaluated.
Within alarm scenarios, no outputs are mapped.
Alarms are not saved as alarm events, i.e. you cannot search
for alarms in the archive. However, the alarm recording is
displayed in the archive as alarm recording (= red time bar).
Alarm recordings are terminated only by the defined alarm
duration.
Recording gaps of 20 to 40 seconds occur when changing from
normal mode to emergency mode or back.