Doc. Title
Author
Page of Pages
ST300/340 OPERATION MANUAL
– LATAM
HG.Park
45 of 146
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.41
26 May. 2015
Suntech International Ltd.
Confidential Document
values as follows:
T2 (interval in driving) of Report Parameter=
120,
ALLOW_PARAM = 0, and
PT_INTERVAL_IN_DRIVING = 30
In the <Case 2> that the parameters have already been set
as above, the device sends the reports every 120 seconds
as long as the vehicle is in a mode of driving. It means that,
in Case 2, the device sends the report at an interval of 120
seconds wherever the vehicle may be.
RPT_INTERVAL_IN
_PARKING
String
Sec
Interval for sending status report in parking
Range : 0 ~ 86400
If 0, report in parking will be sent only one time when vehicle
starts being parked.
RPT_INTERVAL_IN
_DRIVING
String
Sec
Interval for sending status report in driving
Range : 0 ~ 60000
If 0, report in driving will be sent only one time when vehicle
starts being driven.
ALIVE_REPORT_
IN_PARKING
‘0’ or ‘1’
Selection of report string type in parking
If 0, all reports in parking will be STT report.
If 1, all reports except for 1
st
report after changing to parking
will be
‘Alive report’ when vehicle is parked.
SPEED_LIMIT
String
Km/h
Over speed limit for reporting to server
If 0, the device does not check over speed.
If 1 and the vehicle runes over predefined value, device
reports speed alerts once.
Range : 0 ~ 300.00
BUZZER_SPEED_
LIMIT
String
Km/h
Over speed limit for alerting by buzzer
If 0, the device does not check over speed.
Range : 0 ~ 300.00
Not Used
‘0’
Should be 0
Not Used
‘0’
Should be 0
Not Used
‘0’
Should be 0
Not Used
‘0’
Should be 0
GEO_LABEL
String
Geo-fence label
Range: 0 ~ 16 character.
<Note>
This command can be sent as an independent packet.
Please refer to the following example :
ST300PLG;850000;02;
1;1
;1;1;3600;60;1;80.5;75;28.5;2;30.33;1;position 1