Doc. Title
Author
Page of Pages
ST300/340 OPERATION MANUAL
– LATAM
HG.Park
105 of 146
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.41
26 May. 2015
Suntech International Ltd.
Confidential Document
DEV;0;0;0;0;0;0;0;0
<Note>
**
This command starts being applicable to the Software Version 22.
** ‘DEV’ field informs the server about the current status of the device as below.
OUT1
0 = Disable
1 = Enable
OUT2
0 = Disable
1 = Enable
PWR_DN
0 = Normal
1 = Sleep
2 = Deep sleep
BAT_CON
0 = Backup battery is disconnected.
1 = Backup battery is connected.
TRACKING
0 = Stop Tracking
1 = Start Tracking
Anti-Theft
0 = Disable
1 = Enable
Reserved
Reserved
7-5. ACK of Emergency
Once this command is made by the server, the device will stop reporting about the occurrence of emergency. More
details are described in the
‘Meaning’ section
of the table below.
Field
Mark
Value
Meaning
CMD_ID
“AckEmerg”
‘Acknowledge’ of emergency report
The server sends device this command as a response to
inform the device that the server has completed receiving all
the
‘emergency reports’. And then, the device will stop
sending Emergency reports if it is in emergency state.
<Example>
[command] ST300CMD;100850000;02;AckEmerg
[response] ST300CMD;Res;100850000;010;AckEmerg