![SunTech ST300 Series Operation Manual Download Page 140](http://html1.mh-extra.com/html/suntech/st300-series/st300-series_operation-manual_1400856140.webp)
Doc. Title
Author
Page of Pages
ST300/340 OPERATION MANUAL
– LATAM
HG.Park
140 of 146
Concerning
Doc. No.
Rev.
Date
Features and How to set parameters
1.41
26 May. 2015
Suntech International Ltd.
Confidential Document
Shock on Anti-theft Protection
Shock checking can be supported when the following conditions are satisfied:
1.
One input should be set to “Anti-theft2”.
2.
M_SENSOR of the service parameter should be set to use “shock”.
In case that protection against anti-theft starts (with/without door sensor) and that the period of
“shock delay time”
has passed, the shock protection starts working as well.
In a situation of the shock protection, if a shock is checked, the device activates the immobilizer and the buzzer if
they are connected properly. In such a situation, the device will also send the related emergency report to the
server. By pressing the anti-theft button shortly (for 1 second), the emergency situation can be stopped and the
immobilizer and the buzzer can be deactivated.
Temporary deactivation made by Panic
This function is supported if you select
“Anti-theft2” in configuring the device.
If the panic button is pressed, the anti-theft is deactivated temporarily to protect the driver from robbery in a
dangerous situation. Once the anti-theft is deactivated, the anti-theft can be activated only by making a command
named
“RestartAntiTheft2”.