4-18. Coin Machine Parameter
If user of device wants to use a coin machine, the user should set this Parameter (
“Pulse Per Value”).
The user should also set the coin machine as well.
HDR
DEV_ID
VER
PULSE PER VAL
Field
Marks
Value
Meaning
HDR
“ST300CMP”
Command type.
DEV_ID
9 char
Device ID.
VER
“02”
Protocol Version.
PULSE PER VAL
String
This value will be multiplied by the pulse count which comes
from the
‘Coin Machine’.
<Example>
[command]
ST300CMP;100850000;02;100
[response]
ST300CMP;Res;600850779;557;100
<Note>:
**
This function works only on the ST300B model to support the functionality of
‘Coin Machine’.
** If you want to count various coins by coin value such as
’10’ Peso Coin, ‘50’ Peso Coin, ‘100’ Peso Coin, and
‘500’ Peso Coin, please set this function as follows:
Step 1.
‘PULSE PER VAL’ should be set to 10.
Step 2. You should set a pulse for the coin machine by coin value as follows :
a 10 Peso coin
“1”
a 50 Peso coin
“5”
a 100 Peso coin
“10”
a 500 Peso coin
“50”
The ST300B which has been set as above will count every pulse in
‘Ignition ON’ mode, whenever you insert the
coins to
‘Coin Machine.
For example, if you insert a
‘10’ Peso coin and a ‘50’ Peso coin, the ‘Coin Machine’ makes 6 pulses. And then,
the device multiplies 6 pulses by 10, which is the value of
‘PULSE PER VAL’. In other words, you multiply 6 by
10, which is equal to 60.
6 x 10 = 60
By completing to set the coin machine and the device (ST300B) as above, the device is able to report
“60” when