OUT1_TYPE
‘0’ ~ ‘5’ /
‘8’ ~ ‘9’
0 = GPIO.
1 = immobilizer.
2 = Immobilizer & Auto active.
Auto Active means that immobilizer is activated
automatically when the vehicle starts being parked.
3 = Pulse.
4 = LED Out for indicating Call Status. Refer to 9-2-3 of this
document for more detail.
5 = Buzzer.
8 = Immobilizer 2.
9 = Auto Immobilizer 2.
OUT2_TYPE
‘0’ ~ ‘5’ /
‘8’ ~ ‘9’
Same as OUT1_TYPE.
In case of 300F
OUT2_TYPE shall be set as GPIO.
OUT1_ACTIVE
‘0’ or ‘1’
0 = Open when out1 is active.
1 = GND when out1 is active.
OUT2_ACTIVE
‘0’ or ‘1’
0 = Open when out2 is active.
1 = GND when out2 is active.
In case of 300F
OUT2_ACTIVEshall be set to
‘1’.
PULSE1_NO
String
Pulse number when the out1 type is set to pulse:
Range: 0 ~ 9999.
If Pulse Number is 9999, pulsing runs permanently.
PULSE1_ON
String
100ms
Active time of Pulse1:
Range: 0 ~ 9999.
It should be set with an even number.
PULSE1_OFF
String
100ms
Inactive time of Pulse1:
Range: 0 ~ 9999.
It should be set with an even number.
PULSE2_NO
String
Pulse number when out2 type set to pulse:
Range: 0 ~ 9999.
If Pulse Number is 9999, pulsing runs permanently.
PULSE2_ON
String
100ms
Active time of pulse2:
Range: 0 ~ 9999.
It should be set with an even number.
PULSE2_OFF
String
100ms
Inactive time of Pulse2:
Range: 0 ~ 9999.
It should be set with an even number.