The range covers -55 to +125 degrees in Celsius
2ND_LOW_ALERT
String
How to set High Temperature value of the 2nd temperature
sensor to send an alert
The range covers -55 to +125 degrees in Celsius
3RD_ID
String
The Sensor ID of the sensor to
utilize alert function in case
the temperature of the 3
차
온도센서
temperature sensor
changes more than the preset temperature.
3RD_HIGH_ALERT
String
How to set High Temperature value of the 3rd temperature
sensor to send an alert
The range covers -55 to +125 degrees in Celsius
3RD_LOW_ALERT
String
How to set Low Temperature value of the 3rd temperature
sensor to send an alert
The range covers -55 to +125 degrees in Celsius
<Example>
[command]
ST300TAS;100850000;02;28E4D95F0624.0;+20.0;28F5573B0526.0;+22.0;28C4D95F0600
00C5;+12.0;-10.0
[response]
ST300TAS;Res;600850779;557;28E4D95F0624.0;+20.0;28F5573B0526.0;+22.0;28C4D95
F0612.0;-10.0
<Note>:
**
This function works only on ST300A and ST300K.
** The setting value for the temperature is Celsius.
** An alert is sent to the server of the device when the temperature is greater than the pre-set value or is lower
than the pre-set value of the temperature.