V600 METER ERROR CODES
6.3.1 Err
01
Indicates that the VSL Vulcoder is processing an over-ranged signal. An over-ranged signal means
that the load cell output is greater than the maximum that the VSL Vulcoder will accept.
Possible Causes:
1.
The load cells are being over-loaded.
2.
There is moisture in a load cell connector.
3.
One of the VSL Vulcoder-to load cell cables has been damaged.
4.
A load cell has a large Preload Number.
5.
A load cell is faulty.
What to Do:
1.
Perform the Tare Test, (Section 6.2.2).
2.
Check the load cells. Check by disconnecting one load cell at a time. When the faulty load
cell has been disconnected, the meter will read a number instead of the error code.
3.
Check mounting of the load cell per Section 5.2 “Preventive Maintenance and Vulcan
Torque
Specifications”.
6.3.2 Err
02
Indicates that the reading to be displayed is beyond the limitations of the meter’s display.
Possible Causes:
1.
Cal Number set too high.
2.
Tare Weight set too high.
What to Do:
1.
Check and reset the Cal Numbers and Tare weight.