56
CHAPTER 3
3.4.1 MANUAL
SEQUENCING
Manually disconnect all trailer VSL Vulcoders
as shown in figure 3-B, and confirm that if the truck
has two Vulcoders, that one is set up as a Front and one as a Rear per installation instructions, section
1.6.
Figure 3-B: Disconnected Trailer
To Enter the Sequence Chanls Menu:
Enter the Program Menu (Section 3.1)
Press the
CYCLE
button until
SEQUENCE CHANLS
is displayed.
Press the
ENTER
button to select the
SEQUENCE CHANLS
Menu option.
Press the
ENTER
button to start the sequencing mode. The meter will find and sequence the
truck Vulcoders in a few seconds and will display their front (F) or rear (r) designators.
Manually connect each trailer, starting with the most forward trailer connection. As each
connection is made, the meter will verify each connection with either an “
F
” indicating a
front VSL Vulcoder, or an “
r
” indicating a rear VSL Vulcoder.
If the
“SEQ A <- - - - - ->”
appears on the display, no VSL Vulcoders are detected.
Press the
PWR / MENU
button to store the Sequencing information and return to the
SEQUENCE CHANLS
Menu option.
Press the
CYCLE
button to advance to the next Program Main Menu option.
June 21, 2006
VULCAN ON-BOARD SCALES 1-800-237-0022
Doc. 44-10032-001 Rev. C
©
STRESS-TEK, INC. 2006