6.1 VULCAN CHECK-OUT BOX
The Vulcan Check-Out Box can be used to check load cells and the electronics. It works as an
extension to bring load cell connector pins to the side of truck where readings can be conveniently
made. It can also simulate an applied load to the VSL Vulcoder. The Check-Out Box is an optional
equipment item for the Leakage and Resistance Tests (Section 6.2.1 and 6.2.3).
Before using the Check-Out Box, make sure the meter fuses are good. Use a multi-meter to ensure
there is a minimum of 10.4 Vdc at the back of the meter when the system is running. (Make sure the
green plug is plugged in and the meter is turned on.) If there are any error messages displayed, refer to
Section 6.3 “V600 Meter Error Codes”.
Figure 6-A: Vulcan Check-Out Box
To order a Check-Out Box (P/N: 56-10425-001), contact your Vulcan dealer.