CHAPTER 6
97
6.3.7 Err
07
Indicates that a new VSL Vulcoder has been detected or multiple VSL Vulcoders with the same
channel designation have been found.
Possible Causes:
1.
Multiple VSL Vulcoders with the same channel ID have been found.
2. Line
Noise.
What to Do:
1.
System needs to be manually sequenced. Be sure that on two or more channel systems, there is
at least one
rear
VSL Vulcoder, and it is the last VSL Vulcoder in the system.
2.
Turn the meter off and then on to cycle power in system.
3.
Faulty VSL Vulcoder
6.3.8 Err
08
Indicates that the meter has found multiple front VSL Vulcoders.
Possible Causes:
1.
More than one front VSL Vulcoder is attached at the same time. (During sequencing or
powering up the meter).
What to Do:
1.
Disconnect the VSL Vulcoders and then reconnect.
2.
Manually sequence the system.
3.
See electronics installation section for proper installation procedure, (Section 1.6).
June 21, 2006
VULCAN ON-BOARD SCALES 1-800-237-0022
Doc. 44-10032-001 Rev. C
©
STRESS-TEK, INC. 2006