CHAPTER 2
21
2.5
TARE / ZERO BUTTON OPERATION
2.5.1 ZEROES
METER
VALUES
This feature is very useful when entering various numeric values. The meter will automatically zero
the displayed value when the
TARE / ZERO
button is pressed. For example, this can be used when
entering Tare Weights, Set Point values, AZT Range, etc.
To Adjust Meter input values to Zero:
Press the
TARE / ZERO
button to adjust the desired values to zero.
2.5.2
ZEROES METER DISPLAY IN THE "PICK-UP / DELIVERY MODE"
The Tare / Zero Button function enables the user to automatically zero the display for each channel,
at any time during normal operation. Refer to Section 3.2.1 to set the Weight Mode to
Pick-up /
Delivery
.
To Zero The Meter Display:
Press the
TARE / ZERO
button to zero the meter display during normal operation.
Note:
The Tare / Zero button will only zero a channel or combination of channels when
locked on that particular channel or combination of channels.
2.5.3
DISPLAYS GROSS WEIGHT IN THE NET AND PICK-UP /
DELIVERY
MODES
The Tare / Zero Button function enables the user to check the total gross weight while being in the Net
or Pick-up / Delivery Modes. The gross weight will be displayed on the smaller alpha-numeric
display.
Note:
If in the Pick-up / Delivery mode and locked on a channel or combination of channels,
this will also zero what is on the large display. If the meter is in the cycle mode, the gross weight will
be displayed without zeroing the upper display.
To Display The Total Gross Weight While In The Net or Pick-up / Delivery Modes:
Press and hold the
TARE / ZERO
button to display the total gross weight on the smaller
display without switching to the gross weight mode.
June 21, 2006
VULCAN ON-BOARD SCALES 1-800-237-0022
Doc. 44-10032-001 Rev. C
©
STRESS-TEK, INC. 2006