28
CHAPTER 3
Press either the
UP
or
DOWN ARROW
buttons to select the desired channel
display code.
Example:
Press the
ENTER
button to store the display code information and return to the
CONF:
DISP CODE
Menu option.
Press the
CYCLE
button to advance to the next
CONFIGURE SYSTEM
Menu option.
3.2.3
CONFIGURE THE SET POINTS
Set points enable the meter to communicate with the user when a particular weight is reached on a
particular channel or combination of channels. There are two individual set points with capabilities of
driving a relay for each set point configuration. When each set point is activated, the meter display
will show that the set point weight has been reached and if a relay is connected, the meter will activate
the relay which can be connected to a light, horn or any other device used to alert the user.
Procedure to Configure The Set Point:
Enter the
CONFIGURE SYSTEM
Menu, (Section 3.2).
Press the
CYCLE
button until
CONF: SET POINT
is displayed.
Press the
ENTER
button to select the
CONF: SET POINT
option.
June 21, 2006
VULCAN ON-BOARD SCALES 1-800-237-0022
Doc. 44-10032-001 Rev. C
©
STRESS-TEK, INC. 2006