Delay to activate
_ _ 0 Second(s)
US and Canada 800.683.2378, International 904.641.1666
S Series FW 3.02.02
23
Leak detect alarm
not enabled. To
Configuration
menu
CONFIGURATION MENU
continued
Configuration
- Tube Timer
- Reset Totalizer
- Leak Detect
Alarm on tube leak?
Yes
yes/no
set
Alarm on tube leak?
No
yes/no
set
Stop pump on alarm?
Yes
yes/no
set
adjust
set
back
Stop pump on alarm?
No
yes/no
set
To
Configuration
menu
To
Configuration
menu
Select “Yes” to enable the leak
detect alarm, “No” to disable the
leak detect alarm feature.
Enter the number of seconds
between the time a leak is
detected and the time the
alarm is activated. Adjustable
from 0 to 999 seconds.
Select “Yes” to shut pump off in the
event of a leak detect alarm, “No” to
allow the pump to continue to run in
the event of a leak detect alarm.
Sets a value in a menu
NAVIGATION
Moves one step back in
a menu, when permitted
Moves up in a menu, toggles
between options, or increase a value
Moves down in a menu, toggles
between options, or decreases a value
Holding the or button causes the numbers to change rapidly.
LEAK DETECT
The leak detecting components determine when solution is present in the pump
head. When a leak is detected, the tube icon will always appear on the display.
Program how the pump responds when a leak is detected:
1. Set the display alarm, TUBE LEAK, to appear on the screen.
2. Set the pump to stop or continue to run when TUBE LEAK appears.
3. Set a delay (in seconds) for #1 or #2 and/or to activate a relay.
Leak detect is accomplished by sensing conductivity between two metal clips in the tube housing cover. The leak detect
bracket and leak detect tube housing cover must be installed in order to use this option.
The alarm on leak detect is disabled by default. The delay for the alarm to activate is also set to zero by default.
Tip: The leak detect sensitivity is factory pre-set to distinguish between water and typical water treatment chemicals.
Adjust the sensitivity according to the specific chemical utilized in the application. Adjust with the potentiometer located
under the signal cover. Instruction for adjusting are located in
Connections Leak Detect
in this manual.
Manual
0
%
Manual
Tube Leak
%