INSTALLATION
continued
Pump Head
MOUNT PUMP
Recommended mounting is vertical with pump head pointed downward.
Select a dry location (to avoid water intrusion and pump damage) above the solution tank. Best recommended
location is above the solution tank in a vertical position with the pump head pointed downward.
To prevent pump damage in the event of a pump tube leak, never mount the pump vertically with the pump head
up.
To avoid chemical damage from fumes, DO NOT mount pump directly over an open solution tank. Keep
tank covered.
Avoid flooded suction or pump mounted lower than the solution container. Draw solution from the top of the tank.
Pump can run dry without damage. If pump is installed with a flooded suction, a shut-off valve or other device
must be provided to stop flow to pump during service.
Provide 8" clearance to allow pump removal.
To prevent damage, verify with a volt meter that the receptacle voltage corresponds with the pump voltage.
1.
Use the mounting bracket as a template to drill pilot holes in mounting location.
2.
Secure bracket with fasteners or wall anchors. Slide pump into bracket.
Wall Mounting Bracket