US and Canada 800.683.2378, International 904.641.1666
S Series FW 3.02.02
41
CONTROL MODES MENU
continued
PULSE
page 2 of 2
The menu example illustrates
Units
in gallons. For liters, select
Liters
in the
Configuration
menu. When in
Control
mode, liters are represented by
P/L
on the display.
Pulse to Activate
_ _ _ 1 Pulse(s)
adjust
set
set
Set the number of pulses or dry
contacts (1 to 9999) for the pump
to accumulate before activating.
Pump Run Time
_ 20.0 Sec(s)
adjust
set
Meter Rate
_ _ _ 0.0000
adjust
set
P/G
Pump Speed
010 %
adjust
set
To
Pulse
menu
Set the number of seconds (20.0
to 999.9) the pump is to run once
it activates. The minimum run
time is 20.0 seconds.
Set the meter pulse rate or contact
rate. The rate is used to totalize the
process flow for the display.
Set the speed percentage (1
to 100) the pump is to run
while it is activated.
After settings are entered the display returns to the
Pulse
menu and
Alarm Settings
can be programmed.
Pulse
- Program Settings
- Alarm Settings
- Go to Main Menu
Continued from previous page
Sets a value in a menu
NAVIGATION
Moves one step back in
a menu, when permitted
Moves up in a menu, toggles
between options, or increase a value
Moves down in a menu, toggles
between options, or decreases a value
Holding the or button causes the numbers to change rapidly.