S Series FW 3.02.02
www.stenner.com
50
To
PPM Feed Constant Flow
menu
Feed Rate
_ 10.0 PPM
yes/no
set
Specific Gravity
1.14
yes/no
set
CONTROL MODES MENU
continued
PPM FEED – CONSTANT FLOW, FLOW SWITCH
page 3 of 6
Process Flow
_ _ 5.0 GPM
adjust
set
Concentration
_ _ 5.25 %
yes/no
set
Set the
Process Flow
rate.
Set the
Chemical Concentration.
Set the chemical
Specific Gravity
.
Set the dose rate in
Parts Per Million (ppm).
Once the settings have been entered, the
display will return to the
PPM Feed
menu.
Continued from previous page
PPM Feed Constant Flow
- Program Settings
- Go to PPM Feed Menu
Sets a value in a menu
NAVIGATION
Moves one step back in
a menu, when permitted
Moves up in a menu, toggles
between options, or increase a value
Moves down in a menu, toggles
between options, or decreases a value
Holding the or button causes the numbers to change rapidly.