US and Canada 800.683.2378, International 904.641.1666
S Series FW 3.02.02
63
OPERATING DISPLAY
continued
PPM FEED, VARIABLE FLOW
PPM
100
%
Run Pump?
Yes
yes/no
select
PPM
50
%
Prime
PPM
999,999.9
PPM
2.5
Process GPM
Hold for 2 seconds
PPM
OFF
%
To Password Entry Display if display is
locked. To
Main Menu
if unlocked.
If unlocked or password not set.
Metric is displayed if
selected in
Configuration
Pump runs at 100% speed while
the PRIME button is pressed (if
unlocked or password not set).
PPM
0.83
GPH
1.77
oz/min
PPM
22
RPM
Process Gal
PPM
20.0
GPD
PPM
Bar graph along
bottom shows rate of
incoming pulses from
0 to 100%
NAVIGATION IN HALL EFFECT MODE
• If a password is set, the pump controls will lock out after 60 seconds if there is no keypad activity.
• To unlock the pump, press ENTER for 2 seconds. The pump will display a prompt to enter a password.
ENTER
Press and hold for 2 seconds
to go to the Main Menu
BACK
Cycles the display through
the units of output,current
process flow, and total
process flow (gallons or
liters, GPM or LPM).
PRIME
Runs pump at 100% speed
while button is pressed
ON/OFF
Turns pump control ON or OFF
WARNING: DOES NOT remove power.
NOTE: Displayed outputs are approximate and may be rounded off. For some
units of measure, flows close to zero may display zero.