US and Canada 800.683.2378, International 904.641.1666
S Series FW 3.02.02
39
CONTROL MODES MENU
continued
0-10VDC
page 3 of 3
NOTE: Signal alarms are non-latching and will clear automatically when the signal returns to specified operating range.
Alarms activate when settings are exceed.
To
0-10VDC
menu
Yes
No
High Signal Alarm
10.0 VDC
Stop Pump on H ALM?
No
yes/no
set
Alarm on Low Signal?
Continued from previous page
yes/no
set
Yes
No
Low Signal Alarm
_ 0.1 VDC
Stop Pump on L ALM?
No
yes/no
set
Alarm on High Signal?
yes/no
set
To
0-10VDC
menu
Set high signal level. The
alarm activates when the
signal rises above the setting.
Select “Yes” to stop the pump in the
event of a low signal alarm. Select “No”
to allow the pump to continue running
in the event of a low signal alarm.
adjust
set
adjust
set
0-10 VDC
- Program Settings
- Alarm Settings
- Go to Main Menu
Select “Yes” to enable a high signal alarm.
Select “No” to not enable the low signal alarm
and skip to the high signal
Alarm Settings
.
Set low signal level. The
alarm activates when the
signal falls below the setting.
Select “Yes” to stop the pump in the
event of a high signal alarm. Select “No”
to allow the pump to continue running
in the event of a high signal alarm.
Select “No” to not enable the high signal alarm
and return to the 0-10VDC Control menu.
Sets a value in a menu
NAVIGATION
Moves one step back in
a menu, when permitted
Moves up in a menu, toggles
between options, or increase a value
Moves down in a menu, toggles
between options, or decreases a value
Holding the or button causes the numbers to change rapidly.
Yes
Yes