- 17 -
Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety
in accordance with applicable regulations and then
subjected to random sample inspection. STEINEL
guarantees that it is in perfect condition and proper
working order. The warranty period is 36 months,
starting from the date of sale to the consumer.
We will remedy defects caused by material flaws or
manufacturing faults. The warranty will be met by
repair or replacement of defective parts at our own
discretion. The warranty does not cover damage to
wear parts, nor does it cover damage or defects
caused by improper treatment, maintenance or the
use of non-genuine parts. Further consequential
damage to other objects shall be excluded.
Claims under the warranty will only be accepted if
the product is sent fully assembled and well packed
complete with a brief description of the fault as well
as a receipt or invoice (date of purchase and dealer's
stamp) to the appropriate Service Centre.
Repair Service:
Our Customer Service Department
will repair faults not covered by
warranty or after the warranty period.
Please send the product well packed
to your nearest Service Centre.
SensorLight switches ON
when it should not
Change in SensorLight reach
Red LED flashing rapidly
■
Wind is moving trees and bush-
es in the detection zone
■
Cars in the street are detected
■
Sudden temperature changes
due to weather (wind, rain, snow)
or exhaust air from fans or open
windows
■
Change detection zone
■
Change detection zone
■
Adjust detection zone or
install in a different place
■
Differing ambient temperatures
■
Use shrouds to define
detection zone precisely
■
Internal fuse activated
■
Switch SensorLight OFF and
back ON again after 5 sec.
LED light does not come ON
■
Not properly connected
■
Check connection (polarity)
LED light OFF although it is dark
■
Programme 3 or 4 selected
■
Change programme
Troubleshooting
SensorLight without power
SensorLight will not switch ON
SensorLight will not switch OFF
Malfunction
■
Fuse faulty, not switched ON,
break in wiring
■
Short circuit
■
Fit new fuse; switch ON mains
switch; check wiring with volt-
age tester
■
Check connections
■
Twilight control set to night-time
mode during daytime operation
■
Bulb faulty
■
Power switch OFF
■
Fuse faulty
■
Detection zone not properly
targeted
■
Internal electrical fuse has been
activated
(red LED flashing rapidly)
■
Mains terminal not connected
properly
■
Reset (control dial
)
■
Change bulb
■
Switch ON
■
New fuse, check connection
if necessary
■
Re-adjust
■
Switch SensorLight OFF and
back ON again after 5 sec.
■
Firmly press terminal together
■
Permanent movement in the
detection zone
■
Sensor unit is not properly
engaged
■
Check detection zone and
re-adjust if necessary
■
Lightly press sensor unit to clip
it into place
Basic brightness does not go out
at about midnight as desired
■
External light source
(e.g. other motion detector
or light) inactivating the
SensorLight
■
Shade SensorLight from
extraneous light, observe
SensorLight for several days
as it takes time to return to
the correct value
SensorLight will not switch OFF
completely
■
Basic brightness selected
■
Programme selector switch
set to 1 or 4
Cause
Remedy
Manual override function
If a mains switch is installed in the mains supply lead,
the light is capable of the following functions in addition
to the simple ON/OFF function:
Sensor operation
1) Switch light ON (when light is OFF):
Switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON):
Switch OFF and ON once.
The light goes out or switches over to sensor mode.
Manual override
1) Activate manual override:
Turn switch OFF and ON twice. The light is set to stay
on for 4 hours (red LED lights up behind lens). Then it
returns automatically to sensor mode (red LED off).
2) Deactivate manual override:
Switch 1 x OFF and ON. The light goes out or switches
over to sensor mode.
Important:
The switch should be actuated in rapid succession (in
the 0.5 –1 sec. range).
Adjusting the detection zone
The detection zone can be limited to suit require-
ments. The shrouds supplied with the light can be
used to mask out as many lens segments as you
wish. This prevents the light from being activated
unintentionally, e.g. by cars, passers-by etc. and
allows you to target danger spots. The shrouds can
be cut along the pre-grooved vertical divisions.
Then you simply clip them onto the lens.
Directive 02/95/EC.
Operation / Maintenance
The SensorLight is suitable for switching light on
automatically. Weather conditions may affect the way
the SensorLight functions. Strong gusts of wind,
snow, rain or hail may cause the light to come on
when it is not wanted because the sensor is unable
to distinguish sudden changes of temperature from
sources of heat. The detector lens may be cleaned
with a damp cloth if it gets dirty (do not use cleaning
agents).
Technical specifications
Output:
2 x 40 watts max. / G9
LED light approx. 1 W (L 320 Wave)
Voltage:
230-240 V/50 Hz
Angle of coverage:
360° with 90° angle of aperture and sneak-by guard
Sensor reach:
8 max. all round
Time setting:
5 sec. – 15 min.
Twilight setting:
2 - 2000 lux
Programme setting:
Standard programme, filament bulb:
●
Soft light start / no basic brightness
●
LED light ON from twilight setting (L 320 Wave)
Comfort programme, filament bulb:
●
Soft light start + basic brightness
●
LED light ON from twilight setting (L 320 Wave)
C
omfort economy programme, filament bulb:
●
Soft light start + basic brightness to the middle of the night
●
LED light ON from twilight setting
to the middle of the night (L 320 Wave)
Normal programme:
●
no soft light start / no basic brightness
●
LED light ON only in response to movement (L 320 Wave)
Manual override:
selectable (4 hours)
provided switch is connected in mains supply lead
Enclosure:
IP 44 (splashproof)
Declaration of conformity
This product complies with Low Voltage Directive
06/95/EC, EMC Directive 04/108/EC as well as RoHS
4
3
2
1
- 16 -
GB