3 | Connections and Setup
STp.1120n User’s Guide
50
Note:
The ripples must never drift left or right.
9. Tighten the cam roller screw.
10. Print ten (10) Quality Labels from the test menu.
Note:
If wrinkles still appear continue with the adjustment procedure.
11. Loosen the ribbon shield adjustment screws.
12. While printing test labels, slowly adjust the lower shield until the ribbon tension is
constant from left to right and the wrinkles disappear.
Note:
Adjust the ribbon shield by adding tension to the side with wrinkling or light print.
Note:
Adjustment should eliminate side-to-side wrinkles.