2-11
DNW-A220
DNW-A220P
ERROR-14 FAN MOTOR TROUBLE
(FAN MOTOR)
Description:
Malfunction of cooling fan motor was detected.
c
If this error occurred, stop immediately operation of the unit, and turn off the power.
If the unit uses continuously under the fan is stopped state, overhearting inside the unit can cause a fire or
a failure.
Detecting condition:
When the fan motor FG frequency is less than 60% of the specified value.
Sub error message:
None
Possible causes:
.
Fan motor trouble
.
Fan motor FG input port (SY-259/259A board) trouble
.
Harness disconnection
Protecting operation:
None
ERROR-40 DPR-87 BOARD ERROR 1 INITIALIZE CHECK
(DPR-87 BOARD 1)
Description :
The abnormal operation of IC on DPR-87 board was detected.
Detecting condition :
When the diagnostic of each IC at turning on the power is in abnormal state.
Sub error message :
F-CONT
DIGI FIL
SX ENC
SX MEP
ECC ENC
OUTER
SX DEC
For diagnostic of DPR-87 board, refer to section 1-8 (menu number:C24) of maintenance manual part 2
volume 1.
Protecting operation :
Displays only this error.
2-2. Details of Error Messages