3-45
DNW-A220
DNW-A220P
SET button
A white square mark is displayed in the upper-right position of the LCD monitor
when the SET button is pushed. The unit then enters the normal operation state (in
which the normal operation of this unit except a menu system can be performed).
However, the character information (time code or operation status) superimposed
during normal operation is not displayed in this case.
To return to the former state, push the MENU button.
MENU button
The display returns to the error logger display mode when the MENU button is
pushed with the white square displayed in the upper-right position of the LCD
monitor.
Pushing the MENU button in the error logger display mode terminates the error
logger display mode.
Limited-display screen
For the error log of a category that is set to OFF in the menu of setting mode (refer
to Section 3-3-3), information items other than a log number are not displayed.
However, the whole display using the F FWD button is not influenced by the setting.
Ordinary Screen
Only Warning Turned Off
(No limited-display)
3-4. Error Logger Display Mode (M2)
3-3-2. Display Mode
Example of display
and operation
0
[MENU]
ERROR LOGGER
(001/003)
001 REEL TROUBLE-1
002 TAPE TENSION ERROR
003 INTERNAL I/F ERROR
'96 07 03 09:23:10
ERROR LOGGER
(001/003)
001 REEL TROUBLE-1
002 TAPE TENSION ERROR
003 INTERNAL I/F ERROR
'96 07 03 09:23:10
ERROR LOGGER
(001/003)
001 REEL TROUBLE-1
002 TAPE TENSION ERROR
003 INTERNAL I/F ERROR
'96 07 03 09:23:15
0
[SET]
*
*
*
ERROR LOGGER
(001/004)
001 REEL TROUBLE-1
002 TAPE TENSION ERROR
003 INTERNAL I/F ERROR
004 REFERENCE MISSING
'96 07 03 09:23:15
*
ERROR LOGGER
(001/004)
001 REEL TROUBLE-1
002 TAPE TENSION ERROR
003 INTERNAL I/F ERROR
004
'96 07 03 09:23:10
*