3-39
DNW-A220
DNW-A220P
C22 : MULTI LOOP (10TIMES)
This menu selects the multi-loop function enabled or disabled in the maintenance mode, and additionally
selects a video test signal when the multi-loop function is enabled.
The video test signal that can be selected is output from an internal video test signal generator. The video
test signal is the same in type as one described in a C21 : VIDEO TEST SG menu.
OFF:
Normal state (in which no multi-loop operation is performed)
Except OFF: The selected signal is output from a video test signal generator for multi-loop operation.
Multi-loop function setting
To set the multi-loop function, turn the JOG dial while pressing the search button and display the desired
setting.
This setting is valid until the maintenance mode is terminated. However, the C22 : MULTI LOOP
(10TIMES) setting is reset to OFF when the C21 : VIDEO TEST SG setting is changed.
m
.
This menu is set to OFF when the maintenance mode is activated.
.
The output signal during multi-loop operation can also be recorded on the tape or hard disk. In this
case, push the SET button and perform the recording operation with the white square is displayed in the
upper-right position of the LCD monitor.
3-2. TAPE Maintenance Mode (M0)
3-2-4. AUDIO/VIDEO CHECK Mode (C2)
AUDIO/VIDEO CHECK MODE
C22:MULTI LOOP(10TIMES)
OFF
*