1-31
DNW-A220
DNW-A220P
A
B
C
D
E
F
G
1
2
3
4
5
6
7
8
SV-194 Board (B Side)
S100
S101
ON
SV-194 Board
Switches
n
Do not change settings of the factory-use switches.
Ref.No.
Switch name
Description
Factory setting
S100-1
CASSETTE
Turns on and off the function to assume that the cassette
OFF
COMPARTMENT
compartment is locked without the cassette compartment
LOCK
installed
ON: Assumes the cassette compartment is locked
OFF: Normal mode
S100-2
SERVO ERR
Turns on and off the function to detect the servo error
OFF
NOT DET
ON: Servo error is not detected
OFF: Normal mode
S100-3
Factory use
OFF
S100-4
AUTO TRACKING Turns on and off the function to inhibit the auto-tracking
OFF
OFF
during the tape path adjustment
ON: Inhibits the auto-tracking (Tracking VR becomes active)
OFF: Normal mode
S100-5
Factory use
OFF
S100-6
Factory use
OFF
S101
INITIAL
When powered on while pressing this switch, the servo
–––
adjustment data is returned to its default value
1-9. Settings for Internal Switches/Slit Lands