3-46
DNW-A220
DNW-A220P
3-3. Error Logger Display Mode (M2)
3-3-3. Setting Mode
3-3-3. Setting Mode
The setting mode is used to display a menu that limits the display of an error log. In
this menu, the display can be turned on and off for each error log category.
A calendar/clock can also be set in this menu.
m
.
The top and second screens on the right are the examples displayed when the error
logger mode and setting mode are first activated after the power is turned on. The
second-time or later screen is displayed with the preceding display completed.
.
A white square mark is displayed in the upper-right position of the LCD monitor
as in the display mode when the SET button is pushed in the setting mode (except
when “Push SET Button” is displayed during calendar/clock setting). The unit
then enters the normal operation state (in which the normal operation of this unit
except a menu system can be performed). The former state is returned when the
MENU button is pushed.
Entering the setting mode
Push the SET button while pressing the STOP button in the display mode.
Returning to the display mode
Push the SET button again while pressing the STOP button or push the MENU
button.
Setting menu
The seventh to tenth lines on the LCD monitor are a setting menu. The display in
the display mode is left in the first to fifth lines.
Each setting when the power is turned on is all ON.
The error log belonging to a category is limited in display when each item is set to
OFF. (Refer to the “Limited-display screen” on the previous page.)
The changed setting is valid until the power is turned off. How to change the setting
is described below.
(1) Turn the JOG dial and move the
*
mark to the category to be changed in setting.
m
.
In a sub LCD, the contents of the
*
-marked line are displayed on the LCD
monitor.
.
Turn the JOG dial continuously in FORWARD (
2
) direction for the calen-
dar/clock setting. (Refer to the next page.)
(2) To change the setting from ON to OFF, turn the JOG dial in REVERSE (
3
)
direction while pressing the search button.
To change it from OFF to ON, turn the JOG dial in FORWARD (
2
) direction
while pressing the search button.
(3) To change the setting of other categories, repeat steps (1) and (2).
(4) Push the MENU button to terminate the setting mode.
Example of display
and operation
ERROR LOGGER
(001/003)
001 REEL TROUBLE-1
002 TAPE TENSION ERROR
003 INTERNAL I/F ERROR
------------------------
TAPE ERROR ON
WARNING ON
CONDITION ON
'96 07 03 09:23:17
Display mode
Setting mode
ERROR LOGGER
(001/003)
001 REEL TROUBLE-1
002 TAPE TENSION ERROR
003 INTERNAL I/F ERROR
'96 07 03 09:23:15
*
*
0
[STOP]
+
[SET]
[Search]
+
DIAL(
2
)
[Search]
+
DIAL(
2
)
ERROR LOGGER
(001/003)
001 REEL TROUBLE-1
002 TAPE TENSION ERROR
003 INTERNAL I/F ERROR
------------------------
TAPE ERROR ON
WARNING ON
CONDITION ON
'96 07 03 09:23:20
*
0
DIAL(
2
)
ERROR LOGGER
(001/003)
001 REEL TROUBLE-1
002 TAPE TENSION ERROR
003 INTERNAL I/F ERROR
------------------------
TAPE ERROR ON
WARNING OFF
CONDITION ON
'96 07 03 09:23:22
*
0
ERROR LOGGER
(001/003)
001 REEL TROUBLE-1
002 TAPE TENSION ERROR
003 INTERNAL I/F ERROR
------------------------
TAPE ERROR ON
WARNING ON
CONDITION ON
'96 07 03 09:23:24
*
0