1-41
DNW-A220
DNW-A220P
1-14. Battery for Memory Backup
The unit is equipped with a battery for the memory (IC112) backup on the SY-259/259A board. When
replacing, be sure to use the specified part.
Replacement Part:
BT112/SY-259/259A board
Part Description:
Oscillator, crystal (in battery) M4T28-BR12SH1
Part No.:
1-767-156-11
Recommended Replacement Period:
Every seven years
In the memory, the following data is stored. When the battery is dead, or replaced with a new one,
resetting current menu and menu banks 1 to 4 is required. For details on how to reset, refer to the opera-
tion manual supplied with the unit.
When the battery is dead, or replaced, error logs are all cleared.
.
Current menu
.
Menu banks 1 to 4
Replacement
w
When replacing the battery, ensure that a mark on the battery is correctly oriented as shown in the
following figure.
1.
Disconnect the SY-259/259A board. (Refer to Section 1-8-1.)
2.
Insert a flat blade driver between BT112 and IC112 to remove the battery.
3.
Carefully install a new battery, ensuring that the mark's on the BT112 and IC112 are aligned.
4.
Reset the current menu and menu banks. (Refer to the operation manual.)
1-14. Battery for Memory Backup
SY-259/259A board
Mark
Driver
BT112
IC112